MIL-M-38510I5048
TA8LE IV. Programming characteristics for circuit A.
Symbol |
Parameters |
Limits |
Unit |
|||
Min |
Typ |
Max |
||||
VIHH |
Program level input voltage |
11.5 |
11.75 |
12.0 |
V |
|
IIHH |
Program level input current |
Output program pulse |
--- |
--- |
50 |
mA |
Output disable, OD |
--- |
--- |
50 |
|||
All other inputs |
--- |
--- |
10 |
|||
ICCH |
Program supply current |
--- |
--- |
900 |
mA |
|
tP |
Program pulse width |
10 |
20 |
50 |
µS |
|
td |
Delay time |
100 |
--- |
--- |
ns |
|
---- |
Program pulse duty cycle |
--- |
--- |
20 |
% |
|
VP |
Program I verify protect input voltage |
18 |
18.5 |
19 |
V |
|
IP |
Program I verify protect input current |
--- |
--- |
400 |
mA |
|
tPP |
Security fuse programming pulse width |
10 |
40 |
70 |
µS |
|
Security fuse programming duty cycle |
--- |
--- |
50 |
% |
||
tRP |
Rise time of output programming and address pulses |
1 |
1.5 |
10 |
V I µS |
|
tRP |
Rise time of security fuse programming pulses |
1 |
1.5 |
10 |
V I µS |
|
VCCPP |
VCC value during security fuse programming |
5.75 |
6.0 |
6.25 |
V |
|
VCC value for first verify |
4.75 |
5.0 |
5.25 |
|||
VCC value for high VCC verify |
5.4 |
5.5 |
5.6 |
|||
VCC value for low VCC verify |
4.4 |
4.5 |
4.6 |