MIL-M-3851O/371B
Device type O5 Device type O6
OUTPUT CONTROL |
CLOCK |
D |
OUTPUT Q |
L |
↑ |
H |
L |
L |
↑ |
L |
H |
L |
L |
x |
Q O |
H |
x |
x |
z |
H = High level (steady state) H = High level (steady state) L = Low level (steady state) L = Low level (steady state) x = Irrelevent x = Irrelevent
↑= Transition from low to high level ↑= Transition from low to high level
Q O= The level of Q before the indicated steady QO= The level of Q before the indicated steady state input conditions were established. state input conditions were established.
z = High Impedance state z = High Impedance state
Device type O7
PRESET |
DATA |
CLOCK |
OUTPUT CONTROL |
OUTPUT |
PR |
D |
CLK |
OC |
Q |
x |
x |
x |
H |
z |
L |
x |
x |
L |
L |
H |
H |
↑ |
L |
L |
H |
L |
↑ |
L |
H |
H |
x |
L |
L |
Q O |
H = High level (steady state) L = Low level (steady state) x = Irrelevent
↑= Transition from low to high level
Q O= The level of Q before the indicated steady state input conditions were established.
z = High Impedance state
FIGURE 3. Truth tables - Continued.