TABLE III. Group A inspection for device type 05 - Continued.
Terminal conditions (pins not designated are open)
Subgroup |
Symbol |
MIL- STD- 883 method |
Cases A, B, D |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
1 |
2 |
3 |
4 |
Meas. terminal |
Test limits |
||
Case C |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
|||||||
Test No. |
Serial Input A |
Serial Input B |
Output QA |
Output QB |
Output QC |
Output QD |
GND |
Clock |
Clear |
Output QE |
Output QF |
Output QG |
Output QH |
VCC |
Min |
Max |
Unit |
||||
9 TC = 25°C " " " " " " |
tPHL2 " " " " " " " |
3003 (Fig 8) " " " " " " |
181 182 183 184 185 186 187 188 |
G " " " " " " " |
G " " " " " " " |
OUT |
OUT |
OUT |
OUT |
GND " " " " " " " |
F " " " " " " " |
H " " " " " " " |
OUT |
OUT |
OUT |
OUT |
5.0 V " " " " " " " |
CLK to QA CLK to QB CLK to QC CLK to QD CLK to QE CLK to QF CLK to QG CLK to QH |
120 " " " " " " " |
ns " " " " " " " |
|
10 TC=125°C " " " " " " " " " " " " " " " " " " " " " " " |
fMAX |
(Fig 8) |
189 |
G |
G |
" |
" |
" |
OUT |
" |
QH |
3 |
MHz |
||||||||
tPHL1 " " " " " " " |
3003 (Fig 8) " " " " " " |
190 191 192 193 194 195 196 197 |
E, G " " " " " " " |
E, G " " " " " " " |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " |
CLR to QA CLR to QB CLR to QC CLR to QD CLR to QE CLR to QF CLR to QG CLR to QH |
140 " " " " " " " |
ns " " " " " " " |
||
tPLH2 " " " " " " " |
" " " " " " " " |
198 199 200 201 202 203 204 205 |
G " " " " " " " |
G " " " " " " " |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " |
CLK to QA CLK to QB CLK to QC CLK to QD CLK to QE CLK to QF CLK to QG CLK to QH |
120 " " " " " " " |
" " " " " " " " |
||
tPHL2 " " " " " " " |
" " " " " " " " |
206 207 208 209 210 211 212 213 |
" " " " " " " " |
" " " " " " " " |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " |
CLK to QA CLK to QB CLK to QC CLK to QD CLK to QE CLK to QF CLK to QG CLK to QH |
135 " " " " " " " |
" " " " " " " " |
||
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |
NOTES: C = Clock pulse (see figure 8).
D = Momentary ground then 4.5 V to clear register before start of test.
E = Outputs are set to high level prior to measurement of tPHL from clear. F = Input A from figure 8.
G = Input B from figure 8. H = Input C from figure 8.
11 Output voltages shall be either: (a) H = 2.4 V, minimum and L = 0.4 V, maximum when using a high speed checker double comparator; or
(b) H � 1.5 V and L < 1.5 V when using a high speed checker single comparator.
21 Only a summary of attributes data is required.
31 INPUTS: A = 2.0 V and B = 0.7 V.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business