MIL-M-38510/28C
NOTES:
1. The pulse generators have the following characteristics: tr < 10 ns, tf < 10 ns, duty cycle < 50%, ZOUT = 50n.
2. CL = includes probe and jig capacitance.
3. All diodes are 1N916 or equivalent.
4. QA output is illustrated. Relationship of serial input A and B data to other Q outputs is illustrated in the typical shift sequence.
5. Outputs are set to the high level prior to the measurement of tPHL for the clear input.
6. VCC shall be of sufficient amplitude to provide 5 V at device terminal.
Figure 5. Switching test circuits and waveforms for device type 02.