MIL-M-3851O/28C
Device type O3
n+8 = Indicates state after eight clock pulse
L = Low voltage level
H = High voltage level
x = Either high or low voltage level
KEY TO SEQUENCE:
T1 = Clear ( MR LOW) T5 = Load 'L' via D1
T2 = Inhibit (CP HIGH) (D1 LOW, DS HIGH)
T3 = Load logic 'H' via DO
(DO HIGH, DS LOW)
T4 = Load logic 'L' via DO
(DO LOW, DS LOW)
T6 = Load logic 'H' via D1
(D1 HIGH, DS HIGH)
Typical clear-inhibit-load-clear sequence.
Figure 3. Truth tables and timing diagrams - Continued.