TABLE III. Group A inspection for device type 01 - Continued
Terminal conditions (pins not designated are open)
Subgroup |
Symbol |
MIL- STD- 883 method |
Cases A, B, C, D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Meas. Terminal |
Test limits |
Unit |
|
Test No. |
Serial Input |
Input B |
Input C |
VCC |
Input D |
Mode control |
Clock 1 |
Clock 2 |
Output QD |
Output QC |
GND |
Output QB |
Output QA |
Input A |
Min |
Max |
|||||
10 TC= 125°C " |
tPHL " |
3003 (Fig 4) " |
121 122 |
GND GND |
D D |
D D |
5.0 V 5.0 V |
D D |
2.4 V 2.4 V |
GND GND |
C C |
OUT |
OUT |
GND GND |
D D |
CLK 2 to OUT QC CLK 2 to OUT QD |
250 250 |
ns ns |
|||
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |
NOTES: C = Clock pulse, see figure 4.
D = Data pulse, see figure 4.
1/ Output voltages shall be either: (a) H = 2.4 V, minimum and L = 0.4 V, maximum when using a high speed checker double comparator; or
(b) H � 1.5 V and L < 1.5 V when using a high speed checker single comparator.
2/ Only a summary of attributes data is required.