TABLE III. Group A inspection for device type 02 - Continued.
Terminal conditions (pins not designated are open)
Subgroup |
Symbol |
MIL- STD- 883 method |
Cases A, B, C, D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Meas. terminal |
Test limits |
||
Test No. |
Serial Input A |
Serial Input B |
Output QA |
Output QB |
Output QC |
Output QD |
GND |
Clock |
Clear |
Output QE |
Output QF |
Output QG |
Output QH |
VCC |
Min |
Max |
Unit |
||||
9 TC = 25°C " " " " " " " " " |
tPLH2 " " |
Fig 5 " " |
177 178 179 |
G " " |
G " " |
GND " " |
F " " |
H " " |
OUT |
OUT |
OUT |
5.0 V " " |
CLR to QF CLR to QG CLR to QH |
10 " " |
40 " " |
ns " " |
|||||
tPHL2 " " " " " " " |
" " " " " " " " |
180 181 182 183 184 185 186 187 |
" " " " " " " " |
" " " " " " " " |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " |
CLR to QA CLR to QB CLR to QC CLR to QD CLR to QE CLR to QF CLR to QG CLR to QH |
" " " " " " " " |
60 " " " " " " " |
ns " " " " " " " |
|
10 TC = 125°C " " " " " " " " " " " " " " " " " " " " " " " |
fMAX |
(Fig 5) |
188 |
G |
G |
" |
" |
" |
OUT |
" |
QH |
12 |
MHz |
||||||||
tPHL1 " " " " " " " |
3003 (Fig 5) " " " " " " |
189 190 191 192 193 194 195 196 |
E, G " " " " " " " |
E, G " " " " " " " |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " |
CLR to QA CLR to QB CLR to QC CLR to QD CLR to QE CLR to QF CLR to QG CLR to QH |
10 " " " " " " " |
110 " " " " " " " |
ns " " " " " " " |
|
tPLH2 " " " " " " " |
" " " " " " " " |
197 198 199 200 201 202 203 204 |
G " " " " " " " |
G " " " " " " " |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " |
CLK to QA CLK to QB CLK to QC CLK to QD CLK to QE CLK to QF CLK to QG CLK to QH |
" " " " " " " " |
" " " 80 " " " " |
" " " " " " " " |
|
tPHL2 " " " " " " " |
" " " " " " " " |
205 206 207 208 209 210 211 212 |
" " " " " " " " |
" " " " " " " " |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " |
CLK to QA CLK to QB CLK to QC CLK to QD CLK to QE CLK to QF CLK to QG CLK to QH |
" " " " " " " " |
100 " " " " " " " |
" " " " " " " " |
|
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |
NOTES: C = Clock pulse, see figure 5.
D = Momentary ground then 4.5 V to clear register before start of test.
E = Outputs are set to high level prior to measurement of tPHL from clear. F = Input A from figure 5.
G = Input B from figure 5. H = Input C from figure 5.
11 Output voltages shall be either: (a) H = 2.4 V, minimum and L = 0.4 V, maximum when using a high speed checker double checker; or
(b) H � 1.5 V and L < 1.5 V when using a high speed checker single comparator.
21 Only a summary of attributes data is required.
31 Inputs: A = 2.0 V and B = 0.8 V.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744