MIL-M-38510/203E
Word no. |
Enable |
Address |
Data |
|||||||||||
cE 1 |
cE 2 |
A7 |
A6 |
A5 |
A4 |
A3 |
A2 |
A1 |
A0 |
01 |
02 |
03 |
04 |
|
NA |
L |
L |
x |
x |
x |
x |
x |
x |
x |
x |
5/ |
5/ |
5/ |
5/ |
NA |
L |
H |
x |
x |
x |
x |
x |
x |
x |
x |
oc |
oc |
oc |
oc |
NA |
H |
L |
x |
x |
x |
x |
x |
x |
x |
x |
oc |
oc |
oc |
oc |
NA |
H |
H |
x |
x |
x |
x |
x |
x |
x |
x |
oc |
oc |
oc |
oc |
NoTES:
1. NA = Not applicable.
2. x = Input may be high level, low level, or open circuit.
3. oc = open circuit (high resistance output).
4. Program readout can only be accomplished with both enable inputs at low level.
5. The outputs for an unprogrammed device shall be high for circuits A and B, and shall be low for circuit c and G.
FIGURE 2. Truth table (unprogrammed).
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business