MIL-M-38510/190D
TABLE I. Electrical performance characteristics.
Test |
Symbol |
Conditions 1/ 2/ V- = -15 V, V+ = +15 V, VEN = 4.5 V, GND = 0 V, -55°C ≤ TA ≤ +125°C unless otherwise specified |
Device type |
Limits |
Unit |
|
Min |
Max |
|||||
Positive input clamping voltage |
VIC(POS) |
TA = 25°C, V+ = V- = 0 V, IIN = 1 mA |
02, 04, 05, 06 |
1.5 |
V dc |
|
Negative input clamping voltage |
VIC(NEG) |
TA = 25°C, V+ = V- = 0 V, IIN = -1 mA |
02, 04, 05, 06 |
-1.5 |
V dc |
|
Input leakage current 3/ |
IIH |
Measure address inputs sequentially, connect all unused address inputs to GND |
All |
-0.1 |
+1.0 |
µA |
Input leakage current 3/ |
IIL |
Measure address inputs sequentially, connect all unused address inputs to 5 V |
All |
-1.0 |
+0.1 |
µA |
Leakage current into the source terminal of an "OFF" switch |
IS(OFF) |
VS = 10 V, VEN = 0.8 V, All unused sources = -10 V, TA = 25°C |
All |
-1 |
1 |
nA |
VS = 10 V, VEN = 0.8 V, All unused sources = -10 V, -55°C ≤ TA ≤ 125°C |
-50 |
50 |
||||
VS = -10 V, VEN = 0.8 V, All unused sources= +10 V, TA = 25°C |
-1 |
1 |
||||
VS = -10 V, VEN = 0.8 V, All unused sources= +10 V, -55°C ≤ TA ≤ 125°C |
-50 |
50 |
||||
Leakage current into the drain terminal of an "OFF" switch |
ID+(OFF) |
VD = 10 V, VEN = 0.8 V, All unused sources = -10 V, TA = 25°C |
01, 02 |
-20 |
20 |
nA |
03, 04, 05, 06, 07, 08 |
-10 |
10 |
||||
VD = 10 V, VEN = 0.8 V, All unused sources = -10 V, -55°C ≤ TA ≤ 125°C |
01, 02 |
-500 |
500 |
|||
03, 04, 05, 07 |
-250 |
250 |
||||
06, 08 |
-125 |
125 |
See footnotes at end of table.