TABLE III. Group A inspection for device type 01 - Continued.
Symbol |
MIL- STD-833 method |
Cases A,C,D,T, X,Y |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Units |
||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Subgroup 12 TA = 25°C |
||||||||||
Symbol |
A |
G |
B |
H |
C |
I |
VSS |
J |
D |
K |
E |
L |
F |
VDD |
||||||||||
Test No. |
Min |
Max |
||||||||||||||||||||||
tPHL " " " " " |
3003 Fig. 4 " " " " |
131 132 133 134 135 136 |
IN GND " " " " |
OUT |
GND IN GND " " " |
OUT |
GND GND IN GND GND GND |
OUT |
GND " " " " " |
OUT |
GND " " IN GND GND |
OUT |
GND " " " IN GND |
OUT |
GND " " " " IN |
10.0V " " " " " |
A to G B to H C to I D to J E to K F to L |
3 " " " " " |
60 " " " " " |
ns " " " " " " " " " " " " " " " " " " " " " " " |
||||
tPLH " " " " " |
" " " " " " |
137 138 139 140 141 142 |
IN GND " " " " |
OUT |
GND IN GND " " " |
OUT |
GND GND IN GND GND GND |
OUT |
" " " " " " |
OUT |
GND " " IN GND GND |
OUT |
" " " " IN GND |
OUT |
GND " " " " IN |
" " " " " " |
A to G B to H C to I D to J E to K F to L |
" " " " " " |
" " " " " " |
|||||
tTHL " " " " " |
3004 Fig. 4 " " " " |
143 144 145 146 147 148 |
IN GND " " " " |
OUT |
GND IN GND " " " |
OUT |
GND GND IN GND " " |
OUT |
" " " " " " |
OUT |
GND GND GND IN GND GND |
OUT |
" " " " IN GND |
OUT |
GND " " " " IN |
" " " " " " |
G H I J K L |
5 " " " " " |
100 " " " " " |
|||||
tTLH " " " " " |
" " " " " " |
149 150 151 152 153 154 |
IN GND " " " " |
OUT |
GND IN GND " " " |
OUT |
" " IN GND GND GND |
OUT |
" " " " " " |
OUT |
" " " IN GND GND |
OUT |
" " " " IN GND |
OUT |
GND " " " " IN |
" " " " " " |
G H I J K L |
" " " " " " |
" " " " " " |
See notes at end of table.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business