TABLE IV. Group C end point electrical parameters. TA = 25°C
Device type |
Characteristics |
Symbol |
Delta limits 1/ |
Limits |
Unit |
|
Min |
Max |
|||||
01, 04, 05 |
Reference voltage VS = 30 V, TA = +25°C |
VR1, VR2, VR3 |
±2 mV |
6.80 |
7.10 |
V |
02, 06 |
Reference voltage TA = +25°C |
VR1, VR2, VR3 |
±3 mV |
6.70 |
7.20 |
V |
03 |
Reference voltage VS = 15 V, TA = +25°C |
VO |
±3 mV |
9.970 |
10.030 |
V |
07 |
Reference voltage VIN = 10 V, TA = +25°C |
VO |
±3 mV |
4.95 |
5.05 |
V |
08 |
Reference voltage VIN = 12 V, TA = +25°C |
VO |
±3 mV |
6.95 |
7.05 |
V |
09 |
Reference voltage VIN = 15 V, TA = +25°C |
VO |
±3 mV |
9.95 |
10.05 |
V |
1/ Delta limits apply to the measured value (see delta limit definition in MIL-PRF-38535).
5. PACKAGING
5.1 Packaging requirements. For acquisition purposes, the packaging requirements shall be as specified in the contract or order (see 6.2). When actual packaging of materiel is to be performed by DoD personnel, these personnel need to contact the responsible packaging activity to ascertain requisite packaging requirements. Packaging requirements are maintained by the Inventory Control Point's packaging activity within the Military Department of Defense Agency, or within the Military Department's System Command. Packaging data retrieval is available from the managing Military Department's or Defense Agency's automated packaging files, CD-ROM products, or by contacting the responsible packaging activity.
29
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business