TABLE III. Group A inspection for all device type 04.
subgroup |
symbol |
Test no. |
Conditions see figures 3, 4, and 5 unless otherwise specified |
Measured value |
Equations |
Limits |
Unit |
||
Voltage |
Current |
Min |
Max |
||||||
1 TA = +25°C |
VR1 VR2 VR3 |
1 2 3 |
Vs = 30 V Vs = 30 V Vs = 30 V |
IR = .5 mA IR = 1.0 mA IR = 10 mA |
6.80 6.80 6.80 |
7.10 7.10 7.10 |
V |
||
VR current |
4 |
Vs = 30 V |
.5 mA = IR = 10 mA |
VR = VR1 - VR3 |
-9 |
9 |
mV |
||
NO |
5 |
Vs = 30 V |
IR = 1.0 mA |
VR4 |
NO = VR4 |
0 |
20 |
∝V RMs |
|
BW = 10 Hz to 10 kHz |
|||||||||
Is |
6 |
Vs = 40 V |
IR = 0 mA |
4 |
20 |
mA |
|||
2 TA = +85°C |
VR I T |
7 |
Vs = 30 V |
IR = 1.0 mA |
VR5 |
--- |
--- |
--- |
|
2 TA = +125°C |
VR current |
8 9 |
Vs = 30 V Vs = 30 V |
IR = 0.5 mA IR = 10 mA |
VR6 VR7 |
VR = VR6 - VR7 |
-12 |
12 |
mV |
VR I T |
10 |
Vs = 30 V |
IR = 1.0 mA |
VR8 |
VR I T = (VR8 - VR5 ) I 40 |
-15 |
15 |
ppm I °C |
|
3 TA = -55°C |
VR current |
11 12 |
Vs = 30 V Vs = 30 V |
IR = 0.5 mA IR = 10 mA |
VR9 VR10 |
VR = VR9 - VR10 |
-12 |
12 |
mV |
VR I T |
13 |
Vs = 30 V |
IR = 1.0 mA |
VR11 |
VR I T = (VR11 - VR5 ) I 140 |
-1.0 |
1.0 |
ppm I °C |
|
Is |
14 |
Vs = 40 V |
IR = 0 mA |
6 |
40 |
mA |
|||
4 TA = +25°C |
NO |
15 |
Vs = 30 V |
IR = 1.0 mA |
VR12 |
NO = VR12 |
0 |
50 |
∝Vp-p |
BW = 0.1 Hz to 10 Hz |
|||||||||
IsI1 IsI2 |
16 17 |
Vs = 40 V Vs = 9 V |
IR = 0 mA IR = 0 mA |
--- |
200 |
mA |
|||
VR 1I temp cycle |
18 19 20 |
Vs = 30 V Vs = 30 V Vs = 30 V |
IR = 1 mA IR = 1 mA IR = 1 mA |
VR13 VR14 VR15 |
VR = VR13 - VR14 VR = VR14 - VR15 |
-10 -10 |
10 10 |
mV |
1I Following the measurement (VR13), the temperature TA shall be cycled to +125°C for 1 hour and returned to +25°C for measurement (VR14). Following the measurement (VR14), the temperature TA shall be cycled to -55°C for 1 hour and returned to +25°C for measurement (VR15).
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.