TABLE I. Electrical performance characteristics for device types 01, 02, 04, 05, and 06 - Continued.
Test |
Symbol |
Conditions -55°C TA +125°C see 3.5 unless otherwise specified |
0evice type |
Limits |
Unit |
|
Min |
Max |
|||||
Temperature stabilizer supply current |
IS |
VS = 40 V, IR = 0 mA, TA = +25°C |
01,04, 05 |
4 |
20 |
mA |
VS = 40 V, IR = 0 mA, TA = -55°C |
01,04, 05 |
6 |
40 |
|||
Initial temperature stabilizer supply current |
ISI |
9 V VS 40 V, IR = 0 mA, TA = +25°C |
01,04, 05 |
--- |
200 |
mA |
Reference voltage temperature cycling hysteresis |
VR (temp cycle) |
VS = 30 V, IR = 1 mA, see figure 5, -55°C TA +125°C |
01,04, 05 |
-10 |
10 |
mV |
IR = 1 mA, see figure 5, -55°C TA +125°C |
02,06 |
-1 |
1 |
|||
Long term stability |
VR I Time |
VS = 30 V, IR = 1 mA ±10 %, Time = 600 hours, TA = +25°C |
05 |
-20 |
20 |
ppm I 600 hrs |