TABLE III. Group A inspection for all device type 07.
Subgroup |
Symbol |
Test no. |
Measurement value |
Adapter pin number see figure 6 |
Pin measurement |
Equation |
Limits |
Unit |
|||
1 |
2 |
3 |
Min |
Max |
|||||||
1 TA = +25°C |
ICC |
1 |
I1 |
10 V |
0 mA |
0 mA |
1 |
ICC = I1 |
--- |
1.2 |
mA |
VO 1/ |
2 |
V1 |
10 V |
0 mA |
0 mA |
2 |
VO = V1 |
4.950 |
5.050 |
V |
|
VRLINE 2/ |
3 4 |
V2 V3 |
7.2 V 40 V |
0 mA 0 mA |
0 mA 0 mA |
2 2 |
VRLINE = V1 - V2 VRLINE = V1 - V3 |
-0.17 -0.9 |
0.17 0.9 |
mV mV |
|
VRLOAD 2/ |
5 6 7 |
V4 V5 V6 |
10 V 10 V 10 V |
0 mA 10 mA -10 mA |
0 mA 0 mA 0 mA |
2 2 2 |
VRLOAD = V4 - V5 VRLOAD = V4 - V6 |
-5.0 -1.0 |
5.0 1.0 |
mV mV |
|
VTRIM |
8 |
V7 |
10 V |
0 mA |
0 mA |
3 |
VTRIM = V7 |
3.5 |
--- |
V |
|
IOS |
9 |
I2 |
10 V |
0 V |
0 mA |
2 |
IOS = I2 |
-50 |
--- |
mA |
|
2 TA = +125°C |
ICC |
10 |
I3 |
10 V |
0 mA |
0 mA |
1 |
ICC = I3 |
--- |
1.5 |
mA |
VO 1/ |
11 |
V8 |
10 V |
0 mA |
0 mA |
2 |
VO = V8 |
4.9475 |
5.0525 |
V |
|
VRLINE 2/ |
12 13 |
V9 V10 |
7.2 V 40 V |
0 mA 0 mA |
0 mA 0 mA |
2 2 |
VRLINE = V8 - V9 VRLINE = V8 - V10 |
-0.28 -1.5 |
0.28 1.5 |
mV mV |
|
VRLOAD 2/ |
14 15 16 |
V11 V12 V13 |
10 V 10 V 10 V |
0 mA 10 mA -10 mA |
0 mA 0 mA 0 mA |
2 2 2 |
VRLOAD = V11 - V12 VRLOAD = V11 - V13 |
-7.5 -1.75 |
7.5 1.75 |
mV mV |
|
?VO / ?T |
17 |
?VO / ?T = (V8 - V1) / 100 |
--- |
5 |
ppm/°C |
||||||
3 TA = -55°C |
ICC |
18 |
I4 |
10 V |
0 mA |
0 mA |
1 |
ICC = I4 |
--- |
1.5 |
mA |
VO 1/ |
19 |
V14 |
10 V |
0 mA |
0 mA |
2 |
VO = V14 |
4.948 |
5.052 |
V |
|
VRLINE 2/ |
20 21 |
V15 V16 |
7.2 V 40 V |
0 mA 0 mA |
0 mA 0 mA |
2 2 |
VRLINE = V14 - V15 VRLINE = V14 - V16 |
-0.28 -1.5 |
0.28 1.5 |
mV mV |
|
VRLOAD 2/ |
22 23 24 |
V17 V18 V19 |
10 V 10 V 10 V |
0 mA 10 mA -10 mA |
0 mA 0 mA 0 mA |
2 2 2 |
VRLOAD = V17 - V18 VRLOAD = V17 - V19 |
-7.5 -1.75 |
7.5 1.75 |
mV mV |
|
?VO / ?T |
25 |
?VO / ?T = (V14- V1) / 80 |
--- |
5 |
ppm/°C |
||||||
4 TA = +25°C |
NO 3/ |
26 |
N1 |
15 V |
0 mA |
0 mA |
--- |
See figure 7 |
3.5 |
∝V RMS |
1/ Reference voltage is measured immediately after device is turned ON. Changes due to chip warm up are typically less that 0.005 percent.
2/ Line and load regulation are measured on a pulse basis. Pulse is not to exceed 30 ms.
3/ RMS noise is measured with a two pole high pass filter at 10 Hz and a two pole low pass filter at 1 kHz.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744