TA8LE III. Group A inspection for device type 04. - Continued.
Terminal conditions (pins not designated are open)
Subgroup |
Symbol |
MIL-STD- 883 method |
Case 2 |
2 |
3 |
4 |
5 |
7 |
8 |
9 |
10 |
12 |
13 |
14 |
15 |
17 |
18 |
19 |
20 |
Measured terminal |
Limits |
Unit |
|
Cases E and F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Min |
Max |
|||||
Test no. |
1Y |
1YP |
1S |
1RC |
1A |
1A(R) |
18 |
GND |
28 |
2A(R) |
2A |
2RC |
2S |
3YP |
2Y |
VCC |
|||||||
9 TA = +25°C 1/ |
tPLH1 tPHL1 tPLH1 tPHL1 tPLH1 tPHL1 tPLH1 tPHL1 tPLH2 tPHL2 tPLH2 tPHL2 |
3003 (Fig. 3) |
36 37 38 39 40 41 42 43 44 45 46 47 |
OUT " " " OUT OUT |
1Y " " " 1Y 1Y |
4.5 V " " " IN IN |
IN IN GND GND 4.5 V 4.5 V |
GND GND IN IN GND GND |
GND " " " " " " " " " " " |
GND GND IN IN GND GND |
IN IN GND GND 4.5 V 4.5 V |
4.5 V " " " " " IN IN |
2Y " " " 2Y 2Y |
OUT " " " OUT OUT |
5.0 V " " " " " " " " " " " |
1Y " " " 2Y " " " 1Y 1Y 2Y 2Y |
50 " " " " " " " 15 " " " |
ns " " " " " " " " " " " |
|||||
10 TA = +125°C 1/ |
tPLH1 tPHL1 tPLH1 tPHL1 tPLH1 tPHL1 tPLH1 tPHL1 tPLH2 tPHL2 tPLH2 tPHL2 |
3003 (Fig. 3) |
48 49 50 51 52 53 54 55 56 57 58 59 |
OUT " " " OUT OUT |
1Y " " " 1Y 1Y |
4.5 V " " " IN IN |
IN IN GND GND 4.5 V 4.5 V |
GND GND IN IN GND GND |
" " " " " " " " " " " " |
GND GND IN IN GND GND |
IN IN GND GND 4.5 V 4.5 V |
4.5 V " " " IN IN |
2Y " " " 2Y 2Y |
OUT " " " OUT OUT |
" " " " " " " " " " " " |
1Y " " " 2Y " " " 1Y 1Y 2Y 2Y |
60 " " " " " " " 25 " " " |
ns " " " " " " " " " " " |
|||||
11 1/ |
Same tests, terminal conditions, and limits as for subgroup 10, except TA = -55°C. |
1/ For subgroups 9, 10, and 11, the unused output terminals may be open or loaded to facilitate equipment setup and minimize switching of loads as long as there is no effect on the measured parameter.