MIL-M-38510/104C
Device types 01 and 02
Notes:
1. The pulse generators have the following characteristics: ZOUT = 50 ν, tTLH = tTHL ≤ 5 ns, tpl = 500 ns, PRR = 1 MHz, tp2 = 1 μs, PRR = 500 kHz.
2. All strobe inputs are tested according to table III.
3. CL includes probe and jig capacitance.
4. All diodes are 1N916, or equivalent.
FIGURE 3. Switching time test circuit.