TABLE III. Group A inspection for device type 01 - Continued.
Terminal conditions (pins not designated are open)
Subgroup |
Symbol |
MIL-STD- 883 method |
Cases A,B,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Limits |
Unit |
|
Case C |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Min |
Max |
|||||
Test no. |
1A |
1B |
NC |
1Y |
1G |
S |
GND |
2G |
2Y |
NC |
2B |
2A |
-VCC |
+VCC |
|||||||
9 TA = +25°C |
tPLH1 tPLH1 tPHL1 tPHL1 tPLH2 tPLH2 tPLH2 tPLH2 tPHL2 tPHL2 tPHL2 tPHL2 |
3003 (Fig. 3) |
38 39 40 41 42 43 44 45 46 47 48 49 |
IN GND IN GND " " " " " " " " |
100 mV " " " " " " " " " " " |
OUT OUT OUT OUT OUT OUT |
5.0 V GND 5.0 V GND IN GND 5.0 V GND IN GND 5.0 V GND |
5.0 V " " " " " IN IN 5.0 V 5.0 V IN IN |
GND " " " " " " " " " " " |
GND 5.0 V GND 5.0 V GND IN GND 5.0 V GND IN GND 5.0 V |
OUT OUT OUT OUT OUT OUT |
100 mV " " " " " " " " " " " |
GND IN GND IN GND " " " " " " " |
-5.0 V " " " " " " " " " " " |
+5.0 V " " " " " " " " " " " |
1A to 1Y 2A to 2Y 1A to 1Y 2A to 2Y 1G to 1Y 2G to 2Y S to 1Y S to 2Y 1G to 1Y 2G to 2Y S to 1Y S to 2Y |
25 " " " 20 " " " 15 " " " |
ns " " " " " " " " " " " |
|||
10 TA = +125°C |
tPLH1 tPLH1 tPHL1 tPHL1 tPLH2 tPLH2 tPLH2 tPLH2 tPHL2 tPHL2 tPHL2 tPHL2 |
50 51 52 53 54 55 56 57 58 59 60 61 |
IN GND IN GND " " " " " " " " |
" " " " " " " " " " " " |
OUT OUT OUT OUT OUT OUT |
5.0 V GND 5.0 V GND IN GND 5.0 V GND IN GND 5.0 V GND |
5.0 V " " " " " IN IN 5.0 V 5.0 V IN IN |
" " " " " " " " " " " " |
GND 5.0 V GND 5.0 V GND IN GND 5.0 V GND IN GND 5.0 V |
OUT OUT OUT OUT OUT OUT |
" " " " " " " " " " " " |
GND IN GND IN GND " " " " " " " |
" " " " " " " " " " " " |
" " " " " " " " " " " " |
1A to 1Y 2A to 2Y 1A to 1Y 2A to 2Y 1G to 1Y 2G to 2Y S to 1Y S to 2Y 1G to 1Y 2G to 2Y S to 1Y S to 2Y |
40 40 35 35 30 " " " 25 " " " |
" " " " " " " " " " " " |
||||
11 |
Same tests, terminal conditions, and limits as for subgroup 10, except TA = -55°C. |
11 +25 mV applied from input 1A to input 1B or from input 2A to input 2B, as applicable.
21 -25 mV applied from input 1A to input 1B or from input 2A to input 2B, as applicable.
31 0.5 V applied from input 1A to input 1B or from input 2A to input 2B, as applicable.
41 -2.0 V applied from positive input to negative input.