TABLE lll. Group A inspection for device type 01. Terminal conditions (pins not designated are open)
Subgroup |
Symbol |
MlL-STD- 883 method |
Cases A,B,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Limits |
Unit |
|
Case C |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Min |
Max |
|||||
Test no. |
1A |
1B |
NC |
1Y |
1G |
S |
GND |
2G |
2Y |
NC |
2B |
2A |
-VCC |
+VCC |
|||||||
1 TA =+25°C |
VOH |
3006 " " " " " " " " " " " |
1 2 3 4 5 6 7 8 9 10 11 12 |
11 11 21 " " " GND " " " " " |
+3.0 V -3.0 V +3.0 V -3.0 V +3.0 V -3.0 V GND " " " " " |
-400 ∝A " " " " " |
2.0 V 2.0 V 0.8 V 0.8 V 2.0 V 2.0 V GND " " " " " |
2.0 V " " " 0.8 V 0.8 V 2.0 V " " " 0.8 V 0.8 V |
GND " " " " " " " " " " " |
GND " " " " " 2.0 V 2.0 V 0.8 V 0.8 V 2.0 V 2.0 V |
-400 ∝A " " " " " |
GND " " " " " +3.0 V -3.0 V +3.0 V -3.0 V +3.0 V -3.0 V |
GND " " " " " 11 11 21 " " " |
-4.5 V " " " " " " " " " " " |
+4.5 V " " " " " " " " " " " |
1Y " " " " " 2Y " " " " " |
2.4 " " " " " " " " " " " |
V " " " " " " " " " " " |
|||
VOL |
3007 |
13 14 15 16 |
21 21 GND GND |
+3.0 V -3.0 V GND GND |
16 mA 16 mA |
2.0 V 2.0 V GND GND |
2.0 V " " " |
" " " " |
GND GND 2.0 V 2.0 V |
16 mA 16 mA |
GND GND +3.0 V -3.0 V |
GND GND 21 21 |
" " " " |
" " " " |
1Y 1Y 2Y 2Y |
0.4 " " 0.4 |
" " " " |
||||
llH1 |
3010 |
17 18 19 20 |
31 31 GND GND |
+3.0 V -3.0 V GND " |
GND " " " |
" " " " |
GND GND +3.0 V -3.0 V |
GND GND 31 31 |
-5.5 V " " " |
+5.5 V " " " |
1A 1A 2A 2A |
75 " " " |
∝A " " " |
||||||||
llH2 |
21 |
25 mV |
" |
GND |
2.4 V |
" |
GND |
GND |
25 mV |
" |
" |
S |
80 |
" |
|||||||
llH3 |
22 |
" |
" |
GND |
5.5 V |
" |
" |
" |
25 mV |
" |
" |
S |
2 |
mA |
|||||||
llH4 llH4 |
23 24 |
" GND |
" " |
2.4 V GND |
GND " |
" " |
" 2.4 V |
" " |
GND 25 mV |
" " |
" " |
1G 2G |
40 40 |
∝A " |
|||||||
llH5 llH5 |
25 26 |
25 mV GND |
" " |
5.5 V GND |
" " |
" " |
GND 5.5 V |
" " |
GND 25 mV |
" " |
" " |
1G 2G |
100 100 |
" " |
|||||||
llL1 |
3009 |
27 28 29 30 |
41 41 GND GND |
+3.0 V -3.0 V GND " |
" " " " |
GND GND +3.0 V -3.0 V |
GND GND 41 41 |
" " " " |
" " " " |
1A 1A 2A 2A |
-10 " " " |
" " " " |
|||||||||
llL2 llL2 |
31 32 |
-25 mV GND |
" " |
0.4 V GND |
4.5 V 4.5 V |
" " |
GND 0.4 V |
GND " |
GND -25 mV |
" " |
" " |
1G 2G |
-0.7 -0.7 |
-1.6 -1.6 |
mA " |
||||||
llL3 |
33 |
-25 mV |
" |
4.5 V |
0.4 V |
" |
4.5 V |
" |
-25 mV |
" |
" |
S |
-1.4 |
-3.2 |
" |
||||||
lOS lOS |
3011 |
34 35 |
25 mV " |
" " |
GND |
GND GND |
GND GND |
" " |
GND GND |
GND |
" " |
+25 mV " |
" " |
" " |
1Y 2Y |
-18 -18 |
-70 -70 |
" " |
|||
lCCH+ |
3005 |
36 |
" |
" |
5.0 V |
5.0 V |
" |
5.0 V |
" |
" |
" |
" |
+VCC |
+30 |
" |
||||||
lCCH- |
3005 |
37 |
" |
" |
5.0 V |
5.0 V |
" |
5.0 V |
" |
" |
" |
" |
-VCC |
-15 |
" |
||||||
2 |
Same tests, terminal conditions, and limits as subgroup 1, except TA = +125°C. |
||||||||||||||||||||
3 |
Same tests, terminal conditions, and limits as subgroup 1, except TA = -55°C. |
See footnotes at end of device type 01.