TABLE IV. Test conditions for group A inspection for device type 01.
Symbol |
VIH (V) |
VIL (V) |
VITL (V) |
VITH (V) |
VEE (V) |
VEEL (V) |
VCC (V) |
LD1 |
LD2 |
VCCH (V) |
VGG (V) |
TC = +25°C |
+2.4 |
+0.4 |
+1.10 |
+1.80 |
-5.2 |
-3.2 |
+5.0 |
100 n to -2 V |
100 n to GND |
+7.0 |
+2.0 |
TC = +125°C |
+2.4 |
+0.4 |
+0.80 |
+1.80 |
-5.2 |
-3.2 |
+5.0 |
100 n to -2 V |
100 n to GND |
+7.0 |
+2.0 |
TC = -55°C |
+2.4 |
+0.4 |
+1.10 |
+2.00 |
-.5.2 |
-3.2 |
+5.0 |
100 n to -2 V |
100 n to GND |
+7.0 |
+2.0 |
TABLE IVA. Test conditions for group A inspection for device type 02.
Symbol |
VIH (V) |
VIL (V) |
VITL (V) |
VITH (V) |
VEE (V) |
VBB |
VCC (V) |
VCB (V) |
VIHH (V) |
VILH (V) |
VIHL (V) |
VILL (V) |
VILS (V) |
IOH (mA) |
IOLH (mA) |
TC = +25°C |
-0.780 |
-1.850 |
-1.475 |
-1.105 |
-5.2 |
Tie to VBB |
+5.0 |
-5.2 |
+0.220 |
-0.850 |
-1.780 |
-2.850 |
-1.690 |
-2.0 |
+12.0 |
TC = +125°C |
-0.630 |
-1.820 |
-1.400 |
-1.000 |
-5.2 |
Tie to VBB |
+5.0 |
-5.2 |
-0370 |
-0.820 |
-1.630 |
-2.820 |
-2.0 |
+12.0 |
|
TC = -55°C |
-0.880 |
-1.920 |
-1.510 |
-1.255 |
-5.2 |
Tie to VBB |
+5.0 |
-.5.2 |
+0.120 |
-0.920 |
-1.880 |
-2.920 |
-2.0 |
+12.0 |