TABLE III. Group A inspection for device type 01 - Continued.
Subgroup |
Symbol |
MIL-STD- 883 method |
Case E |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Measured terminal |
Limits |
Unit |
|
Case F |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
1 |
2 |
3 |
4 |
|||||||
Case 2 |
2 |
3 |
4 |
5 |
7 |
8 |
9 |
10 |
12 |
13 |
14 |
15 |
17 |
18 |
19 |
20 |
|||||||
Test no. |
2Y |
1Y |
2 Y |
1 Y |
1A |
B |
2A |
VEE |
VCC |
3A |
4A |
3 Y |
4 Y |
4Y |
3Y |
GND |
Min |
Max |
|||||
1 Tc = 25°C |
VOTL " " " " " " " |
41 42 43 44 45 46 47 48 |
LD1 " " " " " " " |
LD1 " " " " " " " |
LD1 " " " " " " " |
LD1 " " " " " " " |
VIH " " " VITH VIH " " |
VITL " " " VIH " " " |
VIH " " " " VITH " " |
VEE " " " " " " " |
VCC " " " " " " " |
VIH VITH VIH |
VIH VITH |
LD1 " " " " " " " |
LD1 " " " " " " " |
LD1 " " " " " " " |
LD1 " " " " " " " |
GND " " " " " " " |
1 Y 2 Y 3 Y 4 Y 1 Y 2 Y 3 Y 4 Y |
-1.6 " " " " " " " |
V " " " " " " " |
||
2 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = 125°C. |
-1.525 |
" |
|||||||||||||||||||
3 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = -55°C. |
-1.635 |
" |
|||||||||||||||||||
1 Tc = 25°C |
VI C " " " " |
49 50 51 52 53 |
-10mA |
-20 mA |
-10 mA |
VEE " " " " |
VCC " " " " |
-10 mA |
-10 mA |
GND " " " " |
1A 2A 3A 4A B |
-1.5 " " " " |
V " " " " |
||||||||||
1 Tc = 25°C |
IIH1 " " " |
3010 |
54 55 56 57 |
VIH |
GND " " " |
VIH |
VEE " " " |
VCC " " " |
VIH |
VIH |
GND " " " |
1A 2A 3A 4A |
50 " " " |
µA " " " |
|||||||||
2 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = 125°C. |
85 |
" |
|||||||||||||||||||
3 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = -55°C. |
85 |
" |
|||||||||||||||||||
1 Tc = 25°C |
IIH2 |
3010 |
58 |
GND |
VIH |
GND |
VEE |
VCC |
GND |
GND |
GND |
B |
200 |
µA |
|||||||||
2 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = 125°C. |
340 |
" |
|||||||||||||||||||
3 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = -55°C. |
340 |
" |
|||||||||||||||||||
IIL1 " " " |
3009 |
59 60 61 62 |
VIL |
VIH " " " |
VIL |
VEE " " " |
VCC " " " |
VIL |
VIL |
GND " " " |
1A 2A 3A 4A |
-3.2 " " " |
" " " " |
mA " " " |
|||||||||
" |
Same tests, terminal conditions as for subgroup 1, except Tc = 125°C. |
-5.5 |
" |
||||||||||||||||||||
" |
Same tests, terminal conditions as for subgroup 1, except Tc = -55°C. |
-3.2 |
" |
||||||||||||||||||||
1 Tc = 25°C |
IIL2 |
3009 |
63 |
VIL |
VEE |
VCC |
GND |
B |
-12.8 |
mA |
|||||||||||||
2 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = 125°C. |
-22.0 |
" |
|||||||||||||||||||
3 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = -55°C. |
-12.8 |
" |
|||||||||||||||||||
1 Tc = 25°C |
BVIN " " " " |
64 65 66 67 68 |
1 mA VIL |
VIL " " " 1 mA |
1 mA VIL |
VEE " " " " |
VCC " " " " |
1 mA VIL |
1 mA VIL |
GND |
1A 2A 3A 4A B |
5.5 " " " " |
V " " " " |
||||||||||
2 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = 125°C. |
5.5 |
" |
|||||||||||||||||||
3 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = -55°C. |
5.5 |
" |
|||||||||||||||||||
1 Tc = 25°C |
ICCL |
3005 |
69 |
GND |
GND |
GND |
VEE |
VCC |
GND |
GND |
GND |
VCC |
25 |
mA |
|||||||||
2 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = 125°C. |
28 |
" |
|||||||||||||||||||
3 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = -55°C. |
28 |
" |
|||||||||||||||||||
1 Tc = 25°C |
ICCH |
3005 |
70 |
5.0 V |
5.0 V |
5.0 V |
VEE |
VCC |
5.0 V |
5.0 V |
GND |
VCC |
16 |
mA |
|||||||||
2 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = 125°C. |
18 |
" |
|||||||||||||||||||
3 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = -55°C. |
18 |
" |
|||||||||||||||||||
1 Tc = 25°C |
IEE |
3005 |
71 |
VEE |
VCC |
GND |
VEE |
-66 |
mA |
||||||||||||||
2 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = 125°C. |
-73 |
" |
|||||||||||||||||||
3 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = -55°C. |
-73 |
" |
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business