TABLE III. Group A inspection for device type 02 - Continued.
Subgroup |
Symbol |
MIL-STD- 883 method |
Case E |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Measured terminal |
Limits |
Unit |
|
Case F |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
1 |
2 |
3 |
4 |
|||||||
Case 2 |
2 |
3 |
4 |
5 |
7 |
8 |
9 |
10 |
12 |
13 |
14 |
15 |
17 |
18 |
19 |
20 |
|||||||
Test no. |
VBB |
1A |
1B |
1Y |
2Y |
2A |
2B |
VEE |
VCC |
3A |
3B |
3Y |
4Y |
4A |
4B |
GND |
Min |
Max |
|||||
1 Tc = 25°C |
VBB |
49 |
VBB |
VBB |
VBB |
VEE |
VCC |
VBB |
VBB |
GND |
VBB |
-1.35 |
-1.23 |
V |
|||||||||
2 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = 125°C. |
-1.24 |
-1.12 |
" |
||||||||||||||||||
3 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = -55°C. |
-1.44 |
-1.32 |
" |
||||||||||||||||||
1 Tc = 25°C |
IIH1 " " " " " " " |
3010 |
50 51 52 53 54 55 56 57 |
VBB " " " " " " " |
VIH VBB " " " |
VBB VIH |
VBB " " " |
VBB " " " " VIH " |
VEE " " " " " " " |
VCC " " " " " " " |
VIH VBB " " " |
VBB " " " " VIH |
VIH VBB " " " |
VBB " " " VIH |
GND " " " " " " " |
1A 2A 3A 4A 1B 2B 3B 4B |
115 " " " " " " " |
µA " " " " " " " |
|||||
2 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = 125°C. |
196 |
" |
|||||||||||||||||||
3 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = -55°C. |
196 |
" |
|||||||||||||||||||
1 Tc = 25°C |
ICBO " " " " " " " |
58 59 60 61 62 63 64 65 |
VBB " " " " " " " |
VEE VBB " " " |
VBB " " " VEE |
VBB VEE VBB " " " |
VBB " " " " VEE |
VEE " " " " " " " |
VCC " " " " " " " |
VBB VEE VBB " " " |
VBB " " " " VEE |
VBB VEE VBB |
VBB " " " VEE |
GND " " " " " " " |
1A 2A 3A 4A 1B 2B 3B 4B |
-1.0 " " " " " " " |
µA " " " " " " " |
||||||
2 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = 125°C. |
-1.0 |
" |
|||||||||||||||||||
3 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = -55°C. |
-1.5 |
" |
|||||||||||||||||||
1 Tc = 25°C |
IOS " " " |
66 67 68 69 |
VBB " " " |
VIL " " " |
VBB " " " |
GND |
GND |
VIL " " " |
VBB " " " |
VEE " " " |
VCC " " " |
VIL " " " |
VBB " " " |
VIL " " " |
VBB " " " |
GND " " " |
1Y 2Y 3Y 4Y |
-40 " " " |
-100 " " " |
mA " " " |
|||
2 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = 125°C. |
-35 |
-100 |
" |
||||||||||||||||||
3 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = -55°C. |
-40 |
-100 |
" |
||||||||||||||||||
1 Tc = 25°C |
ICCL |
3005 |
70 |
VBB |
VIL |
VBB |
VIL |
VBB |
VEE |
VCC |
VIL |
VBB |
VIL |
VBB |
GND |
VCC |
39 |
mA |
|||||
2 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = 125°C. |
39 |
" |
|||||||||||||||||||
3 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = -55°C. |
39 |
" |
|||||||||||||||||||
1 Tc = 25°C |
ICCH |
3005 |
71 |
VBB |
VIH |
VBB |
VIH |
VBB |
VEE |
VCC |
VIH |
VBB |
VIH |
VBB |
GND |
VCC |
52 |
mA |
|||||
2 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = 125°C. |
52 |
" |
|||||||||||||||||||
3 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = -55°C. |
52 |
" |
|||||||||||||||||||
1 Tc = 25°C |
IEE |
3005 |
72 |
VBB |
VBB |
VBB |
VEE |
VCC |
VBB |
VBB |
GND |
VEE |
-40 |
mA |
|||||||||
2 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = 125°C. |
-44 |
" |
|||||||||||||||||||
3 |
" |
Same tests, terminal conditions as for subgroup 1, except Tc = -55°C. |
-40 |
" |
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business