MIL-M-38510/63C
1.3 Absolute maximum ratings.
Supply voltage range:
For VEE ........................................................................... 0 V dc to -7.0 V dc for VEE
For VCC ........................................................................... 0 V dc to +7.0 V dc for VCC
Input voltage range:
Device type 01 ................................................................ +5.0 V dc to GND Device type 02 ................................................................ GND to VEE
Storage temperature range ................................................... -65° to +150°C Maximum power dissipation per gate (PD) 1/:
Device type 01 ................................................................ 145 mW
Device type 02 ................................................................ 130 mW
Lead temperature (soldering, 10 seconds) ............................ +260°C
Thermal resistance, junction to case (eJC) ............................ See MIL-STD-1835
Junction temperature (TJ) 2/.................................................. 165°C Maximum output current:
Device type 01 ................................................................ -50 mA
Device type 02 ................................................................ +24 mA
1.4 Recommended operating conditions.
Supply voltage (VCC) ............................................................. -5.46 V minimum to +5.5 V maximum
Minimum high level input voltage (VIH) .................................. -1.105 V at TA = +25°C (ECL), 2.0 V (TTL) (at 500 linear ft/min) ........................................................ -1.000 V at TA = +125°C (ECL), 2.0 V (TTL) (ft/min) ............................................................................. -1.255 V at TA = -55°C (ECL), 2.0 V (TTL)
Maximum low level input voltage (VIL) ................................... -1.475 V at TA = +25°C (ECL), 0.8 V (TTL) (at 500 linear ft/min) ........................................................ -1.400 V at TA = +125°C (ECL), 0.8 V (TTL) (ft/min) ............................................................................. -1.510 V at TA = -55°C (ECL),0.8 V (TTL)
Normalized fanout (each output) 3/ ...................................... 10 maximum
Case operating temperature range (TC):
(at 500 linear ft/min) ........................................................ -55° to +125°C Case operating temperature range (TC):
(at still air):
Device type 01 ....................................................... -55° to +105°C (case E)
........................................................ -55° to +115°C (case F) Device type 02 ....................................................... -55° to +115°C (case E)
........................................................ -55° to +120°C (case F)
2. APPLICABLE DOCUMENTS
2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed.
1/ Must withstand the added PD due to short-circuit test (e.g., IOS).
2/ Maximum junction temperature shall not be exceeded except for allowable short duration burn-in
screening conditions in accordance with MIL-PRF-38535.
3/ Device will fanout in both high and low levels to the specified number of data inputs on the same device type as that being tested.
2