TA8LE III. Group A inspection for device type 01.
Symbol |
MIL- STD- 883 method |
Cases A,C,D,T,X, Y |
For terminal conditions and limits, see 1/ and 3/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Subgroup 1 TA = 25°C |
Subgroup 2 TA = 125°C |
Subgroup 3 TA = -55°C |
||||||||
Test no. |
1A |
18 |
1Y |
2Y |
28 |
2A |
VSS |
3A |
38 |
3Y |
4Y |
48 |
4A |
VDD |
Min |
Max |
Min |
Max |
Min |
Max |
||||
VIC(pos) 1/ " " " " " " |
1 2 3 4 5 6 7 8 |
1mA |
1mA |
1mA |
1mA |
1mA |
1mA |
1mA |
1mA |
GND " " " " " " " |
1A 18 28 2A 3A 38 48 4A |
1.5 " " " " " " " |
V " " " " " " " |
|||||||||||
VIC(neg) 1/ " " " " " " |
9 10 11 12 13 14 15 16 |
-1mA |
-1mA |
-1mA |
-1mA |
GND " " " " " " " |
-1mA |
-1mA |
-1mA |
-1mA |
1A 18 28 2A 3A 38 48 4A |
-6.0 " " " " " " " |
" " " " " " " " |
|||||||||||
ISS 1/ " " |
3005 " " |
17 18 19 |
GND 15.0V " |
15.0V " GND |
15.0V " GND |
GND 15.0V " |
" " " |
GND 15.0V " |
15.0V " GND |
15.0V " GND |
GND 15.0V " |
15.0V " " |
VSS " " |
-25.0 " " |
-750.0 " " |
nA " " |
||||||||
VOH1 " " " " " " " |
3006 " " " " " " " |
20 21 22 23 24 25 26 27 |
VIL1 5.0V GND " " " " " |
5.0V VIL1 GND " " " " " |
IOH1 " |
IOH1 " |
" " VIL1 5.0V GND " " " |
GND " 5.0V VIL1 GND " " " |
" " " " " " " " |
GND " " " VIL1 5.0V GND " |
" " " " 5.0V VIL1 GND " |
IOH1 " |
IOH1 " |
" " " " " " VIL1 5.0V |
GND " " " " " 5.0V VIL1 |
5.0V " " " " " " " |
1Y 1Y 2Y 2Y 3Y 3Y 4Y 4Y |
4.2 " " " " " " " |
4.2 " " " " " " " |
4.2 " " " " " " " |
V " " " " " " " |
|||
VOH2 " " " " " " " |
" " " " " " " " |
28 29 30 31 32 33 34 35 |
VIL1 5.0V GND " " " " " |
5.0V VIL1 GND " " " " " |
" " VIL1 5.0V GND " " " |
" " 5.0V VIL1 GND " " " |
" " " " " " " " |
" " " " VIL1 5.0V GND " |
" " " " 5.0V VIL1 GND " |
GND " " " " " VIL1 5.0V |
GND " " " " " 5.0V VIL1 |
" " " " " " " " |
1Y 1Y 2Y 2Y 3Y 3Y 4Y 4Y |
4.95 " " " " " " " |
4.95 " " " " " " " |
4.95 " " " " " " " |
" " " " " " " " |
|||||||
VOH3 " " " " " " " |
" " " " " " " " |
36 37 38 39 40 41 42 43 |
VIL2 12.5V GND " " " " " |
12.5V VIL2 GND " " " " " |
" " VIL2 12.5V GND " " " |
" " 12.5V VIL2 GND " " " |
" " " " " " " " |
" " " " VIL2 12.5V GND " |
" " " " 12.5V VIL2 GND " |
GND " " " " " VIL2 12.5V |
GND " " " " " 12.5V VIL2 |
12.5V " " " " " " " |
1Y 1Y 2Y 2Y 3Y 3Y 4Y 4Y |
11.25 " " " " " " " |
11.25 " " " " " " " |
11.25 " " " " " " " |
" " " " " " " " |
|||||||
VOL1 " " " |
3007 " " " |
44 45 46 47 |
VIH1 GND " " |
VIH1 GND " " |
IOL1 |
IOL1 |
" VIH1 GND " |
" VIH1 GND " |
" " " " |
" " VIH1 GND |
" " VIH1 GND |
IOL1 |
IOL1 |
GND " " VIH1 |
GND " " VIH1 |
5.0V " " " |
1Y 2Y 3Y 4Y |
0.5 " " " |
0.5 " " " |
0.5 " " " |
" " " " |
See footnotes at end of device type 03.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business