TA8LE III. Group A inspection for device type 04. - Continued
Terminal conditions (pins not designated may be H > 2.0 V or L < 0.8 V or open).
Subgroup |
Symbol |
MIL- STD-883 method |
Cases A,8,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Meas. terminal |
Test limits |
||
Case C |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Min |
Max |
Unit |
||||
Test No. |
1A |
18 |
2A |
28 |
2C |
2Y |
GND |
3Y |
3A |
38 |
3C |
1Y |
1C |
VCC |
|||||||
1 TC = 25°C |
VIC |
53 |
GND |
-12 mA |
4.5 V |
1C |
-1.5 |
V |
|||||||||||||
2 |
Same tests, terminal conditions and limits as for subgroup 1, except TC = 125°C and VIC tests are omitted. |
||||||||||||||||||||
3 |
Same tests, terminal conditions and limits as for subgroup 1, except TC = -55°C and VIC tests are omitted. |
||||||||||||||||||||
9 " " " " " |
tPHL " " |
3003 (Fig. 4) " |
54 55 56 |
IN |
GND |
IN |
GND |
GND |
OUT |
GND " " |
OUT |
IN |
GND |
GND |
OUT |
GND |
5.0 V " " |
1A to 1Y 2A to 2Y 3A to 3Y |
3 " " |
20 " " |
ns " " |
tPLH " " |
" " " |
57 58 59 |
IN |
GND |
IN |
GND |
GND |
OUT |
" " " |
OUT |
IN |
GND |
GND |
OUT |
GND |
" " " |
1A to 1Y 2A to 2Y 3A to 3Y |
3 " " |
25 " " |
" " " |
|
10 TC = 125°C " " " " |
tPHL " " |
" " " |
60 61 62 |
IN |
GND |
IN |
GND |
GND |
OUT |
" " " |
OUT |
IN |
GND |
GND |
OUT |
GND |
" " " |
1A to 1Y 2A to 2Y 3A to 3Y |
3 " " |
24 " " |
" " " |
tPLH " " |
" " " |
63 64 65 |
IN |
GND |
IN |
GND |
GND |
OUT |
" " " |
OUT |
IN |
GND |
GND |
OUT |
GND |
" " " |
1A to 1Y 2A to 2Y 3A to 3Y |
3 " " |
27 " " |
" " " |
|
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business