TA8LE III. Group A inspection for device type 03. - Continued
Terminal conditions (pins not designated may be H > 2.0 V or L < 0.8 V or open).
Subgroup |
Symbol |
MIL- STD-883 method |
Cases A,8,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Meas. terminal |
Test limits |
||
Case C |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Min |
Max |
Unit |
||||
Test No. |
1A |
18 |
1G |
1C |
1D |
1Y |
GND |
2Y |
2A |
28 |
2G |
2C |
2D |
VCC |
|||||||
1 TC = 25°C " " |
VIC " " " |
53 54 55 56 |
GND " " " |
-12 mA |
-12 mA |
-12 mA |
-12 mA |
4.5 V " " " |
28 2G 2C 2D |
-1.5 " " " |
V " " " |
||||||||||
2 |
Same tests, terminal conditions and limits as for subgroup 1, except TC = 125°C and VIC tests are omitted. |
||||||||||||||||||||
3 |
Same tests, terminal conditions and limits as for subgroup 1, except TC = -55°C and VIC tests are omitted. |
||||||||||||||||||||
9 TC = 25°C " " |
tPHL |
3003 |
57 |
IN |
GND |
2.4 V |
GND |
GND |
OUT |
GND |
5.0 V |
1A to 1Y |
3 |
20 |
ns |
||||||
tPHL |
(Fig. 5) |
58 |
" |
OUT |
IN |
GND |
2.4 V |
GND |
GND |
" |
2A to 2Y |
3 |
20 |
" |
|||||||
tPLH |
" |
59 |
IN |
GND |
2.4 V |
GND |
GND |
OUT |
" |
" |
1A to 1Y |
3 |
25 |
" |
|||||||
tPLH |
" |
60 |
" |
OUT |
IN |
GND |
2.4 V |
GND |
GND |
" |
2A to 2Y |
3 |
25 |
" |
|||||||
10 TC = 125°C " " |
tPHL |
" |
61 |
IN |
GND |
2.4 V |
GND |
GND |
OUT |
" |
" |
1A to 1Y |
3 |
24 |
" |
||||||
tPHL |
" |
62 |
" |
OUT |
IN |
GND |
2.4 V |
GND |
GND |
" |
2A to 2Y |
3 |
24 |
" |
|||||||
tPLH |
" |
63 |
IN |
GND |
2.4 V |
GND |
GND |
OUT |
" |
" |
1A to 1Y |
3 |
27 |
" |
|||||||
tPLH |
" |
64 |
" |
OUT |
IN |
GND |
2.4 V |
GND |
GND |
" |
2A to 2Y |
3 |
27 |
" |
|||||||
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |
For Parts Inquires call Parts Hangar, Inc (727) 493-0744