TABLE III. Group A inspection for device type 03 - Continued.
Terminal conditions (pins not designated may be high � 2.0 V; low s 0.7 V; or open).
1/ Apply ┐ ┌ - - 2.5 V min/5.5 V max. Pulse prior to test.
└───┘ 0 V
2/ IIL limits in µA are as follows:
Parameter |
Circuit |
|||||
A |
F |
B |
C |
0 |
E |
|
O/C |
-10/-200 |
-400 max |
-400 max |
-180/-420 |
-400 max |
0/-400 |
Clock |
-400 max |
-400 max |
-400 max |
-160/-400 |
-400 max |
0/-400 |
0ata |
-75/-250 |
-75/250 |
-400 max |
-100/-340 |
-75/250 |
-120/-360 |
3/ For circuits C and 0, IOS limits shall be -15/-100 mA. For circuit E, IOS limits shall be -40/-225 mA.
4/ A = 3.0 V minimum. B = 0.0 V or GN0.
5/ Tests shall be performed in sequence, attributes data only.
6/ X = Indeterminate output voltage.
7/ Output voltages shall be: H > 1.5 V
L < 1.5 V
8/ fMAX, minimum limit specified is the frequency of the input pulse. The output frequency shall be one half of the input frequency.