MIL-M-38510/3250
NOTES:
1. All diodes are 1N3064 or equivalent.
2. Output control input pulse characteristics: Vgen = 3.0 ±0.2 V, tI � 15 ns, tO � 6 ns, tP(input) � 200 ns, and PRR � 1 MHz.
3. For the standard test circuit, CL = 50 pF ±10%. For the alternate load circuit, CL = 50 pF ±10% for tPZL and tPZH
and CL = 15 pF minimum for tPLZ and tPHZ. All capacitive load values include jig and probe capacitance.
4. The diodes and resistors shown within the dotted area are optional. When the diodes and resistors are used, VBIAS shall be 5.5 V for all tests except for tPHZ; for tPHZ tests, VBIAS shall be -0.6 V.
5. When using the alternate load circuit, the appropriate switch positions for the three state tests are listed in the table below.
Test |
S1 |
S2 |
tPZL |
Closed |
Open |
tPLZ |
Closed |
Closed |
tPZH |
Open |
Closed |
tPHZ |
Closed |
Closed |
FIGURE 3. Three state switching test circuit and waveforms for device type 02 - Continued.