MIL-M-38510/3250
NOTES:
1. Enable pulse has the following characteristics: Vgen = 3.0 ±0.2 V, tO ≤ 6 ns.
2. 0 input pulse has the following characteristics: Vgen = 3.0 ±0.2 V, tI ≤ 15 ns, tO ≤ 6 ns, tsetup = 5 ns, thold = 20 ns, tP = 25 ns
3. All diodes are 1N3064 or equivalent.
4. The diode and resistor shown within the dotted area are optional. When the diode and resistor are used, VBIAS
shall be 5.5 V for all tests except for tPHZ; for tPHZ tests, VBIAS shall be -0.6 V.
5. CL = 50 pF ±10% (including probe and jig capacitance).
6. Switches S1 and S2 are closed for tPLH1 and tPHL1, when using the alternate load circuit.
FIGURE 3. Switching test circuit (tPLH1, tPHL1) for device type 02 - Continued.