TABLE III. Group A inspection for device type 05 - Continued. 1/
Subgroup |
Symbol |
MIL- STD- 883 method |
Cases A,B,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Test limits |
Unit |
|
Case C |
3 |
2 |
1 |
14 |
13 |
12 |
11 |
10 |
9 |
8 |
7 |
6 |
5 |
4 |
Min |
Max |
|||||
Test no. |
Clock 1 |
D1 |
Clear 1 |
VCC |
Clear 2 |
D2 |
Clock 2 |
Preset 2 |
Q2 |
Q 2 |
GND |
Q 1 |
Q1 |
Preset 1 |
|||||||
10 TC=+125°C |
tPHL |
3003 (Fig. 10) |
102 CKT A 102 CKT B 103 CKT A 103 CKT B 104 CKT A 104 CKT B 105 CKT A 105 CKT B |
IN IN J J |
5.0 V " " " " " " " |
IN IN J J |
J J IN IN |
OUT OUT |
OUT OUT |
GND " " " " " " " |
OUT OUT |
OUT OUT |
J J IN IN |
Clear1/Q1 Clear1/Q1 Preset 1/Q1 Preset 1/Q1 Clear2/Q2 Clear2/Q2 Preset 2/Q2 Preset 2/Q2 |
10 " " " " " " " |
200 120 200 120 200 120 200 120 |
ns " " " " " " " |
||||
tPLH |
3003 (Fig. 11) |
106 CKT A 106 CKT B 107 CKT A 107 CKT B |
IN IN |
IN(G) IN(G) |
B B |
" " " " |
B B |
IN(G) IN(G) |
IN IN |
5.0 V 5.0 V |
OUT OUT |
" " " " |
OUT OUT |
5.0 V 5.0 V |
Clock1/Q1 Clock1/Q1 Clock2/Q2 Clock2/Q2 |
" " " " |
150 85 150 85 |
" " " " |
|||
tPHL |
108 CKT A 108 CKT B 109 CKT A 109 CKT B |
IN IN |
IN(H) IN(H) |
B B |
" " " " |
B B |
IN(H) IN(H) |
IN IN |
5.0 V 5.0 V |
OUT OUT |
" " " " |
OUT OUT |
5.0 V 5.0 V |
Clock1/Q1 Clock1/Q1 Clock2/Q2 Clock2/Q2 |
" " " " |
200 120 200 120 |
" " " " |
||||
tPLH |
3003 (Fig. 12) |
110 CKT A 110 CKT B 111 CKT A 111 CKT B |
IN IN |
IN(G) IN(G) |
5.0 V 5.0 V |
" " " " |
5.0 V 5.0 V |
IN(G) IN(G) |
IN IN |
B B |
OUT OUT |
" " " " |
OUT OUT |
B B |
Clock1/Q1 Clock1/Q1 Clock2/Q2 Clock2/Q2 |
" " " " |
150 85 150 85 |
" " " " |
|||
tPHL |
112 CKT A 112 CKT B 113 CKT A 113 CKT B |
IN IN |
IN(H) IN(H) |
5.0 V 5.0 V |
" " " " |
5.0 V 5.0 V |
IN(H) IN(H) |
IN IN |
B B |
OUT OUT |
" " " " |
OUT OUT |
B B |
Clock1/Q1 Clock1/Q1 Clock2/Q2 Clock2/Q2 |
" " " " |
200 120 200 120 |
" " " " |
||||
11 |
Same tests, terminal conditions, and limits as for subgroup 10, except TC=+55°C |
NOTE: A = normal clock pulse, B = momentary GND, then 4.5 V,
J = input pulse, tp � 100 ns, PRR = 0 MHz, VOL = 0 V, VOH = 4.5 V.
1/ Terminal conditions (pins not designated may be H � 2.0 V, or L ≤ 0.8 V, or open).
2/ Tests shall be performed in sequence.
3/ Input voltages shown are: A = 2.4 V minimum and B = 0.4 V maximum.
4/ Output voltages shall be either: (a) H = 2.4 V, minimum and L = 0.4 V, maximum when using a high speed checker double comparator; or
(b) H � 1.5 V and L ≤ 1.5 V when using a high speed checker single comparator.
5/ fMAX, minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half of the input frequency.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business