MIL-M-38510/21F
Device type 05
Positive logic: Low input to preset sets Q to high level Low input to clear sets Q to low level Preset and clear are independent of clock
NOTES:
1. tn = Bit time before clock pulse.
2. tn+1 = Bit time after clock pulse.
Description for device type 05
Input information is transferred to the output on the positive edge of the clock pulse. Clock triggering occurs at a voltage level of the clock pulse and is not directly related to the transition time of the positive going pulse. After the clock input threshold voltage has been passed, the data input (D) is locked out.
Figure 2. Truth tables and device descriptions - Continued.