MIL-M-38510/21F
NOTES:
1/ Clear or preset input pulse characteristics: Vgen = 3.0 V ±0.2 V, t0 = 15 ns, t1 = 15 ns, tP(CLEAR) = tP(PRESET) =
100 ns, PRR = 0.5 MHz and ZOUT = 50 n.
2/ CL = 50 pF minimum and includes probe and jig capacitance.
3/ RL = 4 kn ±5% and C1 = 30 pF minimum.
4/ All diodes are 1N916 or equivalent.
5/ When testing clear to output switching, preset input shall have a negative pulse; when testing preset to output switching, clear input shall have a negative pulse (see table III).
FIGURE 8. Clear and preset switching test circuit for device type 04.