MIL-M-38510/204F
4.9 Programming procedure for circuit G. The programming characteristics on Table IVC and the following procedures shall be used for programming.
a. Connect the device in the electrical configuration of programming. The waveforms on figure 5c and the programming characteristics of table IVC shall apply to these procedures.
b. Select the desired word by applying high or low levels to the appropriate address inputs. Disable the device by applying a high level to one or more active low chip enable inputs. NOTE: Address and enable inputs must be driven with TTL logic levels during programming and verification.
c. Increase VCC from nominal to VCCP (10.5 ±0.5 V) with a slew rate limit of IRR (1.0 to 10.0 V/µs). Since
VCC is the source of the current required to program the fuse, as well as the ICC for the device at the programming voltage, it must be capable of supplying 750 mA at 11.0 volts.
d. Select the output where a logical high is desired by raising that output voltage to VOP (10.5 ±0.5 V). Limit the slew rate to IRR (1.0 to 10.0 V/µs). This voltage change may occur simultaneously with the VCC increase to VCCP, but must precede it. It is critical that only one output at a time be programmed since the
internal circuits can only supply programming current to one bit at a time. Outputs not being programmed
must be left open or connected to a high impedance source of 20 kn minimum (remember that the outputs of the device are disabled at this time).
e. Enable the device by taking the chip enable(s) to a low level. This is done with a pulse PWE for 10 µs.
The 10 µs duration refers to the time that the circuit (device) is enabled. Normal input levels are used and rise and fall times are not critical.
f. Verify that the bit has been programmed by first removing the programming voltage from the output and then reducing VCC to 5.0 V (±0.25 V). The device must be enabled to sense the state of the outputs. During verification, the loading of the output must be within specified IOL and IOH limits.
g. If the device is not to be tested for VOH over the entire operating range subsequent to programming, the verification of step f is to be performed at a VCC level of 4.0 volt ( ±0.2 V ). VOH, during the 4 volt verification, must be at least 2.0 volts. The 4 volt VCC verification assures minimum VOH levels over the
entire operating range.
h. Repeat steps 4.9b through 4.9f for each bit to be programmed to a high level. If the procedure is
performed on an automatic programmer, the duty cycle of VCC at the programming voltage must be limited to a maximum of 25%. This is necessary to minimize device junction temperatures. After all selected bits are programmed, the entire contents of the memory should be verified.
i. For class S and B devices, if any bit does not verify as programmed it shall be considered a programming reject.
27
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business