TABLE III. Group A inspection for devices type 02 and 04.
Terminal conditions (outputs not designated are open or resistive coupled to GND or voltage; inputs not designated are z 2.0 V, low s 0.8 V, or open).
Subgroup |
Symbol |
MIL- STD- 883 method |
Cases E,F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Measured terminal |
Test limits |
Unit |
|
Test no. |
A6 |
A5 |
A4 |
A3 |
A0 |
A1 |
A2 |
GND |
04 |
03 |
02 |
01 |
CE |
A8 |
A7 |
VCC |
Min |
Max |
|||||
1 TC = 25°C |
ICC |
3005 |
47 |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
5.5V |
VCC |
140 |
mA |
|||||
I0S 2/ 14/ |
3011 " " " |
48 49 50 51 |
11/ 17/ " " " |
11/ 17/ " " " |
11/ 17/ " " " |
11/ 17/ " " " |
11/ 17/ " " " |
11/ 17/ " " " |
11/ 17/ " " " |
" " " " |
GND |
GND |
GND |
GND |
0.5V " " " |
11/ 17/ " " " |
11/ 17/ " " " |
" " " " |
04 03 02 01 |
-10 " " " |
-100 " " " |
" " " " |
|
2 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = 125°C and VIC tests are omitted. |
||||||||||||||||||||||
3 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = -55°C and VIC tests are omitted. |
||||||||||||||||||||||
7 |
Func- tional test |
3014 |
52 |
5/ |
5/ |
5/ |
5/ |
5/ |
5/ |
5/ |
GND |
5/ |
5/ |
5/ |
5/ |
5/ |
5/ |
5/ |
5/ |
0utputs |
5/ |
||
8 |
Same tests, terminal conditions, and limits as for subgroup 7, except TC = 125°C and -55°C. |
||||||||||||||||||||||
9 TC = 25°C |
tPLH1 tPHL1 |
GALPAT (Fig. 4) GALPAT (Fig. 4) |
53 54 |
6/ 6/ |
6/ 6/ |
6/ 6/ |
6/ 6/ |
6/ 6/ |
6/ 6/ |
6/ 6/ |
GND " |
8/ " |
8/ " |
8/ " |
8/ " |
GND GND |
6/ 6/ |
6/ 6/ |
6/ 6/ |
0utputs " |
16/ " |
||
tPLH2 tPHL2 |
Sequen- tial (Fig. 4) Sequen- tial (Fig. 4) |
55 56 |
7/ 7/ |
7/ 7/ |
7/ 7/ |
7/ 7/ |
7/ 7/ |
7/ 7/ |
7/ 7/ |
" " |
" " |
" " |
" " |
" " |
7/ 7/ |
7/ 7/ |
7/ 7/ |
7/ 7/ |
" " |
" " |
|||
10 |
Same tests, terminal conditions, and limits as for subgroup 9, except TC = 125°C. |
||||||||||||||||||||||
11 |
Same tests, terminal conditions, and limits as for subgroup 9, except TC = -55°C. |
See footnotes at end of table.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business