MIL-M-38510/201D
NOTES:
1. Pins 12 and 14 shall be left open.
2. Terminal conditions shall be as specified on table III.
3. C1 = .05 µF ±10 percent; R1 = 51 n ±5 percent; R2 = 470 n ±5 percent; R3 = 1 kn ±5 percent; CL = 30 pF minimum including jig and probe capacitance.
FIGURE 5. Switching time test circuit.
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.