TABLE III. Group A inspection for device type 02 - Continued.
Symbol |
MIL- STD-833 method |
Case A,C,D,T,X,Y |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Unit |
|||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Subgroup 9 TA = 25°C |
Subgroup 10 TA = 125°C |
Subgroup 11 TA = -55°C |
|||||||||
Symbol |
A |
B |
J |
NC |
E |
F |
VSS |
G |
H |
I |
EN |
C |
D |
VDD |
|||||||||||
Test No. |
Min |
Max |
Min |
Max |
Min |
Max |
|||||||||||||||||||
tTHL " " " " " " " " " |
3004 Fig. 3 " " " " " " " " |
126 127 128 129 130 131 132 133 134 135 |
GND IN 5.0V GND " " " " " " |
GND 5.0V IN GND " " " " " " |
OUT " " " " " ‘ " " " |
GND " " " " IN 5.0V GND " " |
GND " " " " 5.0V IN GND " " |
GND " " " " " " " " " |
GND " " " " " " IN 5.0V GND |
GND " " " " " " 5.0V IN GND |
IN GND " " " " " " " " |
5.0V " " " " " " " " IN |
GND GND GND IN 5.0V GND " " " " |
GND GND GND 5.0V IN GND " " " " |
5.0V " " " " " " " " " |
J " " " " " " " " " |
10 " " " " " " " " " |
200 " " " " " " " " " |
18 " " " " " " " " " |
280 " " " " " " " " " |
10 " " " " " " " " " |
200 " " " " " " " " " |
ns " " " " " " " " " |
||
tTLH " " " " " " " " " |
" " " " " " " " " " |
136 137 138 139 140 141 142 143 144 145 |
" IN 5.0V GND " " " " " " |
" 5.0V IN GND " " " " " " |
" " " " " " ‘ " " " |
" " " " " IN 5.0V GND GND GND |
" " " " " 5.0V IN GND GND GND |
" " " " " " " " " " |
" " " " " " " IN 5.0V GND |
" " " " " " " 5.0V IN GND |
IN GND " " " " " " " " |
5.0V " " " " " " " " IN |
" " " IN 5.0V GND " " " " |
" " " 5.0V IN GND " " " " |
" " " " " " " " " " |
" " " " " " " " " " |
" " " " " " " " " " |
" " " " " " " " " " |
" " " " " " " " " " |
" " " " " " " " " " |
" " " " " " " " " " |
" " " " " " " " " " |
" " " " " " " " " " |
||
Subgroup 12 TA = 25°C |
|||||||||||||||||||||||||
tPHL " " " " " " " " " |
3003 Fig. 3 " " " " " " " " |
146 147 148 149 150 151 152 153 154 155 |
GND IN 10.0V GND " " " " " " |
GND 10.0V IN GND " " " " " " |
OUT " " " " " " " " " |
GND " " " " IN 10.0V GND " " |
GND " " " " 10.0V IN GND " " |
GND " " " " " " " " " |
GND " " " " " " IN 10.0V GND |
GND " " " " " " 10.0V IN GND |
IN GND " " " " " " " " |
10.0V " " " " " " " " IN |
GND GND GND IN 10.0V GND " " " " |
GND GND GND 10.0V IN GND " " " " |
10.0V " " " " " " " " " |
I to J A to J B to J C to J D to J E to J F to J G to J H to J EN to J |
6 9 " " " " " " " " |
120 180 " " " " " " " " |
ns " " " " " " " " " |
||||||
tPLH " " " " " " " " " |
" " " " " " " " " " |
156 157 158 159 160 161 162 163 164 165 |
" IN 10.0V GND " " " " " " |
" 10.0V IN GND " " " " " " |
" " " " " " " " " " |
" " " " " IN 10.0V GND " " |
" " " " " 10.0V IN GND " " |
" " " " " " " " " " |
" " " " " " " IN 10.0V GND |
" " " " " " " 10.0V IN GND |
IN GND " " " " " " " " |
10.0V " " " " " " " " IN |
" " " IN 10.0V GND " " " " |
" " " 10.0V IN GND " " " " |
" " " " " " " " " " |
I to J A to J B to J C to J D to J E to J F to J G to J H to J EN to J |
10 14 " " " " " " " " |
200 280 " " " " " " " " |
" " " " " " " " " " |
||||||
tTHL " " " " " " " " " |
3004 Fig. 3 " " " " " " " " |
166 167 168 169 170 171 172 173 174 175 |
" IN 10.0V GND " " " " " " |
" 10.0V IN GND " " " " " " |
" " " " " " " " " " |
" " " " " IN 10.0V GND GND GND |
" " " " " 10.0V IN GND GND GND |
" " " " " " " " " " |
" " " " " " " IN 10.0V GND |
" " " " " " " 10.0V IN GND |
IN GND " " " " " " " " |
10.0V " " " " " " " " IN |
" " " IN 10.0V GND " " " " |
" " " 10.0V IN GND " " " " |
" " " " " " " " " " |
J " " " " " " " " " |
5 " " " " " " " " " |
100 " " " " " " " " " |
" " " " " " " " " " |
See footnotes at end of device type 02.