TABLE III. Group A inspection - Continued.
Subgroup |
Symbol |
Test no. |
Test conditions (undesignated terminals are open) |
Relays energized |
Measured terminal |
Device |
Test Figure |
Limits |
Unit |
|||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
Min |
Max |
||||||||
2 TA = 125°C |
VIC |
124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 |
GND " " " " 24 V " " " " |
GND " " " " " |
-10 mA 4.5 V " " " " -10 mA 4.5 V " " " -10 mA 4.5 V " " " |
4.5 V " " " -10 mA 4.5 V " " " " " " " " " " |
4.5 V " " " " -10 mA |
4.5 V -10 mA 4.5 V " " " " -10 mA 4.5 V " " " -10 mA 4.5 V " " |
GND " " " " " " " " " " " " " " " |
4.5 V " " " " 24 V " " " " " " " " " " |
4.5 V 4.5 V -10 mA 4.5 V " " " " -10 mA 4.5 V " " " -10 mA 4.5 V 4.5 V |
4.5 V " " " " " " " " " |
4.5 V " " " -10 mA 4.5 V " " " -10 mA |
4.5 V " " -10 mA 4.5 V " " " " -10 mA 4.5 V " " " -10 mA 4.5 V |
GND " " " " " |
24 V " " " " " " " " " " " " " " " |
K1 " " " " " |
3 6 11 14 4 5 3 6 11 14 13 3 6 11 14 13 |
01 |
3 " " " " " " " " " " " " " " " |
-1.7 " " " " " " " " " " " " " " " |
V " " " " " " " " " " " " " " " |
||||
02 |
||||||||||||||||||||||||||
03 |
||||||||||||||||||||||||||
IOFF |
140 141 142 143 144 145 |
" " " " " " |
GND " " " " " |
GND 2 V GND 2 V |
2 V GND |
4.5 V 4.5 V |
4.5 V 4.5 V GND 2 V |
GND " " " |
" " " " " " |
4.5 V 4.5 V 24 V " " " |
GND " " " |
GND 2 V |
4.5 V " " " |
2 V GND 2 V GND |
GND 2 V GND 2 V |
GND " " " " " |
" " " " " " |
K1 K1 K2 " " " |
1 1 16 16 9 9 |
01 |
" " " " " " |
500 " " " " " |
∝A " " " " " |
|||
03 |
||||||||||||||||||||||||||
VOH |
146 147 148 149 150 151 152 153 154 155 156 157 |
" " " " GND " " " " " " " |
" " " " |
4.5 V " " " 2 V GND 4.5 V 4.5 V |
4.5 V " " " |
GND 2 V GND 2 V |
2 V GND 4.5 V 4.5 V 2 V GND 4.5 V 4.5 V |
" " " " " " " " " " " " |
4.5 V " " " 24 V " " " " " " " |
4.5 V 4.5 V 2 V GND 4.5 V 4.5 V 2 V GND |
4.5 V " " " " " " " |
GND 2 V GND 2 V GND 2 V GND 2 V |
4.5 V " " " " " 2 V GND |
" " " " |
" " " " " " " " " " " " |
K1 " " " |
7 7 10 10 2 2 15 15 7 7 10 10 |
01 |
" " " " " " " " " " " " |
19 " " " " " " " " " " " |
V " " " " " " " " " " " |
|||||
02 |
||||||||||||||||||||||||||
VCESAT1 |
158 159 160 161 162 163 |
600 mA 600 mA 24 V " " " |
GND " GND " " " |
0.8 V 4.5 V 4.5 V 0.8 V |
0.8 V 0.8 V |
4.5 V 0.8 V |
GND " " " |
" " " " " " |
4.5 V 4.5 V 600 mA 600 mA 24 V 24 V |
GND " " " |
0.8 V 4.5 V |
4.5 V " " " |
0.8 V " " " |
4.5 V 0.8 V 0.8 V 4.5 V |
GND GND " " " " |
15 V 15 V 24 V 24 V 600 mA 600 mA |
15 V 15 V 24 V " " " |
K3 K3 K4 K4 K4 K4 |
1 1 9 9 16 16 |
01 |
" " " " " " |
0.9 " " " " " |
" " " " " " |
|||
03 |
||||||||||||||||||||||||||
VCESAT2 |
164 165 166 167 168 169 |
GND " " " |
600 mA |
0.8 V 4.5 V |
0.8 V 0.8 V |
4.5 V 0.8 V 0.8 V 4.5 V |
600 mA 600 mA |
" " " " " " |
4.5 V 4.5 V 15 V " " " |
600 mA 600 mA |
0.8 V 4.5 V 4.5 V 0.8 V |
4.5 V " " " |
0.8 V " " " |
4.5 V 0.8 V |
600 mA |
15 V " " " " " |
15 V 15 V 24 V " " " |
K1 K1 |
10 7 2 7 10 15 |
01 |
" " " " " " |
" " " " " " |
" " " " " " |
|||
02 |
||||||||||||||||||||||||||
VOC |
170 171 172 173 |
" " " " |
10 mA |
" " " " |
4.5 V " " " |
10 mA |
" " " " |
GND " " " |
10 mA |
4.5 V " " " |
5.5 V " " " |
4.5 V " " " |
4.5 V " " " |
10 mA |
GND " " " |
2 7 10 15 |
02 |
" " " " |
1.5 " " " |
" " " " |
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business