TA8LE III. Group A inspection for device type 06 - Continued.
Subgroup |
Symbol |
Test no. |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Notes |
Measured terminal |
Test limits |
Unit |
|
G |
1A |
1Y |
18 |
1C |
1E |
GND |
Sub |
2E |
2C |
28 |
2Y |
2A |
VCC |
Min |
Max |
||||||
9 TA = +25°C |
tD tD tS tS tR tR tF tF |
127 128 129 130 131 132 133 134 |
A A A A |
8 8 8 8 |
GND GND GND GND |
GND " " " " " " " |
GND GND GND GND |
8 8 8 8 |
A A A A |
See figure 8 for test circuit and waveforms " " " " |
5 10 5 10 5 10 5 10 |
15 15 23 23 20 20 15 15 |
ns " " " " " " " |
||||||||
tPLH1 " " " |
135 136 137 138 |
3 V IN 3 V IN |
IN 3 V |
OUT OUT |
" " " " |
OUT OUT |
IN 3 V |
4.5 V " " " |
See figure 6 for test circuit and waveforms |
2 to 3 1 to 3 13 to 12 1 to 12 |
30 " " " |
" " " " |
|||||||||
tPHL1 " " " |
139 140 141 142 |
3 V IN 3 V IN |
IN 3 V |
OUT OUT |
" " " " |
OUT OUT |
IN 3 V |
4.5 V " " " |
" " " " |
2 to 3 1 to 3 13 to 12 1 to 12 |
15 " " " |
" " " " |
|||||||||
tPLH3 " " " |
143 144 145 146 |
3 V IN 3 V IN |
IN 3 V |
Connect to 18 Connect to 18 |
OUT OUT |
" " " " |
OUT OUT |
Connect to 28 Connect to 28 |
IN 3 V |
4.5 V " " " |
See figure 7 for test circuit and waveforms |
2 to 5 1 to 5 13 to 10 1 to 10 |
65 " " " |
" " " " |
|||||||
tPHL3 " " " |
147 148 149 150 |
3 V IN 3 V IN |
IN 3 V |
Connect to 18 Connect to 18 |
OUT OUT |
" " " " |
OUT OUT |
Connect to 28 Connect to 28 |
IN 3 V |
4.5 V " " " |
" " " " |
2 to 5 1 to 5 13 to 10 1 to 10 |
50 " " " |
" " " " |
|||||||
tTLH2 tTLH2 tTHL2 tTHL2 |
151 152 153 154 |
3 V 3 V 3 V 3 V |
IN IN |
Connect to 18 Connect to 18 |
OUT OUT |
" " " " |
OUT OUT |
Connect to 28 Connect to 28 |
IN IN |
" " " " |
" " " " |
5 10 5 10 |
20 " " " |
" " " " |