MIL-M-38510/1298
NOTES:
1. The pulse generator shall have the following characteristics: PRR = 1 MHz, tp = 0.5 µs, Zout � 50 n.
2. When testing device 01 or 06, connect output Y to transistor base and ground the substrate terminal.
3. RL = 47 n ±5% carbon.
4. CL = 100 pF minimum, including probe and jig capacitance.
5. R1 = 51 n ±5% carbon.
FIGURE 7. Switching time waveforms (TTL gates and transistors combined) for device types 01 and 06.
19