MIL-M-38510/126C
TABLE III. Group A inspection - Continued.
NOTES:
12/ VN = 2.5 V. Equation for CMR is as follows:
CMR = 20 Log [ 5.2 V (201) / I ( EX - EY - 5.2) I ] Test number 19: EX = E17, EY = E16
Test number 50: EX = E40, EY = E39
Test number 81: EX = E63, EY = E62
13/ VN = 0.5 V to 3.5 V. Equation for AVS is as follows: AVS = 20 Log ( VN (201) / I EX I )
Test number 101: EX = E73
Test number 118: EX = E84
Test number 135: EX = E95
14/ VN = 2.5 V. Equation for PSRR is as follows: PSRR = 20 Log [ VIN (201) / I ( EX - EY ) I ]
Test number 102: ( EX - EY ) = ( E75 - E74 )
Test number 119: ( EX - EY ) = ( E86 - E85 ) Test number 136: ( EX - EY ) = ( E97 - E96 )
15/ Increase voltage on +C.S. until V shutdown σ 0.4 V. Record V +C.S.
16/ See figure 4.
52