MIL-M-38510/122C
TABLE III. Group A inspection - Continued.
1/ VCM is achieved by algebraically subtracting the common mode voltage ( VCM ) from each supply and algebraically adding the common mode voltage to V (For example: for VCM = -10 V, then +VCC = +25 V,
-VCC = -5 V, V = 10 V).
2/ Using the ac test circuit, the +VIO(ADJ) will force the output voltage to a voltage greater than +1 mV.
The -VIO(ADJ) will force the output voltage to voltage less than - 1 mV.
3/ The VIO(ADJ) test will be performed as follows: The tester will measure VIO and make a determination as to whether VIO is positive or negative. If VIO is positive, the tester will check for VIO(ADJ) to 1 mV more negative than zero volts. If VIO is negative, the tester will check for VIO(ADJ) to 1 mV more positive than zero volts. The limits specified in this table indicate the minimum adjustability required for a device having VIO equal to the maximum limit.
4/ ±IIB (test numbers 43 through 48), device type 07 is not tested.
5/ Device types 01, 04, 05, 06, 07, and 08: IOUT = ±5 mA. Device types 02 and 03: IOUT = ±10 mA.
6/ Device types 01 and 03: AV = 5; device types 02, 04, and 05: AV = 1; device types 06 and 07: AV = 3.
7/ At +25°C, tests 77 and 78, +SR and -SR, device type 05: 50 V/µs minimum.
8/ At +125°C, test 79 and 80, TR(tr) and TR(tf), device type 05: 60 ns maximum.
9/ At +125°C, tests 81 and 82, TR(+OS) and TR(-OS), device type 05: +50.0% maximum.
10/ At +125C, tests 83 and 84, +SR and -SR, device type 05: +45V/µs minimum.
11/ At -55°C, tests 85 and 86, TR(tr) and TR(tf), device type 05: +60.0 ns maximum.
12/ At -55°C, tests 87 and 88, TR(+OS) and TR(-OS), device type 05: +50% maximum.
13/ At -55°C, tests 89 and 90, +SR and -SR, device type 05: +45.0 V/µs minimum.
14/ For device types 02, 03, 04, 05 and 06, which have a bandwidth control pin, no additional external compensation capacitance shall be used.
15/ At +25°C, tests 91 and 92, +tS and -tS, device type 05: 1.0 µs maximum, device types 06, 07, and 08: 1.1 µs maximum.
16/ Tests 93 through 96, which require a read and record measurement plus a calculation, may be omitted except when subgroup 13 is being accomplished for group A sampling inspection and group B (class S) inspection.
5. PACKAGING
5.1 Packaging requirements. For acquisition purposes, the packaging requirements shall be as specified in the contract or order (see 6.2). When actual packaging of materiel is to be performed by DoD personnel, these personnel need to contact the responsible packaging activity to ascertain requisite packaging requirements. Packaging requirements are maintained by the Inventory Control Point's packaging activity within the Military Department of Defense Agency, or within the Military Department's System Command. Packaging data retrieval is available from the managing Military Department's or Defense Agency's automated packaging files, CD-ROM products, or by contacting the responsible packaging activity.
43