MIL-M-385101122C
TABLE I. Electrical performance characteristics - Continued.
11 Device type 06 shall be free of oscillation when operated at gains of 3 or greater with no external compensation.
21 Tests at common mode VCM = 0, VCM = -10 V, and VCM = +10 V.
31 See table IV for end-point test conditions.
41 Device type 07 is not tested at TA = -55°C
51 Input offset current temperature sensitivity is guaranteed by IIO end-point limits at TA = -55°C and +125°C.
61 Note that gain is not specified at VIO(ADJ) extremes. Some gain reduction is usually seen at VIO(ADJ) extremes.
For closed loop application (closed loop gain less than 1,000), the open loop tests (AVS) prescribed herein should guarantee a positive, reasonable linear, transfer characteristic. They do not, however, guarantee that the open loop is linear, or even positive, over the operating range. If either of these requirements exist (positive
open loop gain or open loop gain linearity), they should be specified in the contract or purchase order as additional requirements (see 6.2).
71 The limits specified are for devices with offset voltages equal to the maximum limit. For devices with offset voltages less than the limit, offset adjust capability will be tested to guarantee adjustability to 1 mV beyond zero.
11
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business