NOTES:
1. All resistors are ±0.1% tolerance and all capacitors are ±10% tolerance unless otherwise specified.
2. Precautions shall be taken to prevent damage to the device under test during insertion into socket
and change of state of relays (i.e. disable voltage supplies, current limit ±VCC, etc).
3. Compensation capacitors should be added as required for test circuit stability. Two general methods
for stability compensation exist. One method is with a capacitor for nulling amp feedback. The other
method is with a capacitor in parallel with the 49.9 kν closed loop feedback resistor. 8oth methods should not be used simultaneously. Proper wiring procedures shall be followed to prevent unwanted coupling
and oscillations, etc. Loop response and settling time shall be consistent with the test rate such that
any value has settled for at least 5 loop time constants before the value is measured.
4. Adequate settling time should be allowed such that each parameter has settled to within 5% of its final value.
5. All relays are shown in the normal de-energized state.
6. The nulling amplifier shall be a M38510/10101XXX. Saturation of the nulling amplifier is not allowed
on tests where E (pin 5) value is measured.
7. The load resistors 2050 ν and 11.1 kν yield effective load resistances of 2 kν and 10 kν respectively.
8. Any oscillation greater than 300 mV in amplitude (peak-to-peak) shall be cause for device failure.
FIGURE 3. Test circuit for static tests.
12