MIL-M-38510I102C
NOTES
1. Unless otherwise specified:
VIN = V+ = VCC = 12 V, V- = 0 V, IL = 1 mA, RSC = 0 ν, C1 = 100 pF, and CREF = 0
2. Resistor values required to set output voltage.
a. For VOUT = 2 to 7 V dc, R1, R2, R3, and R4 are determined as follows: VOUT = VREF x (R2 I (R1 + R2)), VREF I (R1 + R2) = 1 mA,
(R1 x R2) I (R1 + R2) = R3 ≤ 10 kν, R4 = Open circuit
b. For VOUT = 7 to 37 V dc, R1, R2, R3, and R4 are determined as follows: VOUT = VREF x ((R3 + R4) I R4), VOUT I (R3 + R4) = 1 mA,
(R3 x R4) I (R3 + R4) = R1 ≤ 10 kν, R2 = Open circuit
c. For the purpose of this specification, the following table shall be used to determine the resistor value required to obtain a given nominal output voltage.
VOUT |
R1 S1(A) |
R2 S1(B) |
R3 S1(C) |
R4 S1(D) |
2 V |
5.15 kν |
2 kν |
1.45 kν |
8 |
5 V |
2.15 kν |
5 kν |
1.50 kν |
8 |
7.5 V |
0.33 kν |
8 |
0.35 kν |
7.15 kν |
3.7 V |
5.77 kν |
8 |
29.85 kν |
7.15 kν |
If 1 percent resistors are used, nominal VOUT will be achieved within ±5 percent.
3. RL chosen to obtain required IL for given nominal output voltage.
4. TC VOUT:
25°C to 125°C = 100 ((VOUT @ 25°C - VOUT @ 125°C) I VOUT @ 25°C) + 100°C = % I °C.
5. TC VOUT:
-55°C to 25°C = 100 ((VOUT @ 55°C - VOUT @ 25°C) I VOUT @ 25°C) + 100°C = % I °C.
6. Precautions shall be taken to prevent damage to the device under test during insertion into
socket and change of switch positions (e.g., disable power supplies, current limit, VCC, V+, V-, etc.).
FIGURE 5. Test circuit for static and dynamic tests - Continued.
19
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business