MIL-M-38510/76C
NOTES:
1. S0 and S1, tsetup = 11 ns.
2. The clear pulse has the following characteristics: tP(clear) = 12 ns, and PRR ≤ 1 MHz.
3. The data pulse has the following characteristics: tP(data) = 8 ns, tsetup = 5 ns, thold = 3 ns and PRR ≤ 1 MHz.
4. The clock pulse has the following characteristics: tP(clock) = 10 ns, and PRR ≤ 1 MHz for tPHL1 measurement and 2 MHz for tPLH2 and tPHL2 measurements.
5. For each clock to output tPLH2 and tPHL2 measurement the clear input is momentarily grounded then raised to and held at 3 V minimum.
6. For fMAX measurement at -55°C and 125°C the clock input PRR ≤ 56 MHz and the shift right input PRR ≤ 28
MHz; at 25°C the clock input PRR ≤ 70 MHz and the shift right input PRR ≤ 35 MHz.
7. Load circuits or a given output are only required where the specific test given in table III indicated OUT on that output. Load circuits may otherwise be omitted.
Figure 4. Switching time test circuit and waveforms for device types 01 - Continued.
15
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business