MIL-M-38510/7568
Device type 01 Device type 02
Operating mode |
Inputs |
Output |
||
MR |
CP |
Dn |
Yn |
|
Reset (clear) |
L |
x |
x |
L |
Load "1" |
H |
t |
H |
H |
Load "0" |
H |
t |
L |
L |
Device type 03 Device type 05
Operating mode |
Inputs |
Output |
||
OE |
CP |
Dn |
Yn |
|
Load "1" |
L |
t |
H |
H |
Load "0" |
L |
t |
L |
L |
Hold (do nothing) |
H |
t |
x |
No change |
H |
x |
x |
No change |
Device types 04 and 06
Function |
Inputs |
Outputs |
|||
OE |
CP |
Dn |
Yn |
Yn * |
|
Hold |
H |
H |
L |
z |
z |
Hold |
H |
H |
H |
z |
z |
Load |
H |
t |
L |
z |
z |
Load |
H |
t |
H |
z |
z |
Data available |
L |
t |
L |
L |
H |
Data available |
L |
t |
H |
H |
L |
No change |
L |
H |
L |
No change |
No change |
No change |
L |
H |
H |
No change |
No change |
*NOTE: The inverted output (Yn) applies to device type 06.
H = High voltage level L = Low voltage level x = Irrelevant
z = High impedance
t = Transition from low-to-high voltage level
FIGURE 2. Truth tables.