MIL-M-38510/7538
TA8LE I. Electrical performance characteristics - Continued.
Test and MIL-STD-883 test method |
Symbol |
Test Conditions 1/ -55°C = TC = +125°C +3.0 V = VCC = +5.5 V unless otherwise specified |
Device type 2/ |
VCC |
Group A subgroups |
Limits 1/ |
Unit |
||
Min |
Max |
||||||||
Propagation delay time, SD or CD to Q or Q 3003 |
tPHL, tPLH 4/ 5/ 13/ 14/ |
CL = 50 pF minimum RL = 500ν See figure 4 |
02, 04 |
3.0 V |
9, 11 |
1.0 |
12.0 |
ns |
|
10 |
1.0 |
14.0 |
|||||||
M |
02, 04 |
9 |
1.0 |
12.0 |
|||||
D |
02, 04 |
1.0 |
12.0 |
||||||
P, L, R |
02, 04 |
1.0 |
12.0 |
||||||
F |
02 |
1.0 |
13.0 |
||||||
CL = 50 pF minimum RL = 500ν See figure 4 |
02, 04 |
4.5 V |
9, 11 |
1.0 |
10.0 |
ns |
|||
10 |
1.0 |
12.0 |
|||||||
M |
02, 04 |
9 |
1.0 |
10.0 |
|||||
D |
02, 04 |
1.0 |
10.0 |
||||||
P, L, R |
02, 04 |
1.0 |
10.0 |
||||||
F |
02 |
1.0 |
10.0 |
||||||
Propagation delay time, MR to Q 3003 |
tPHL 4/ 5/ 13/ 14/ |
CL = 50 pF minimum RL = 500ν See figure 4 |
07, 08 |
3.0 V |
9, 11 |
1.0 |
11.5 |
ns |
|
10 |
1.0 |
13.5 |
|||||||
M |
07 |
9 |
1.0 |
11.5 |
|||||
D |
07 |
1.0 |
11.5 |
||||||
P, L, R |
07 |
1.0 |
11.5 |
||||||
F |
07 |
1.0 |
13.0 |
||||||
CL = 50 pF minimum RL = 500ν See figure 4 |
07, 08 |
4.5 V |
9, 11 |
1.0 |
9.0 |
ns |
|||
10 |
1.0 |
11.0 |
|||||||
M |
07 |
9 |
1.0 |
9.0 |
|||||
D |
07 |
1.0 |
9.0 |
||||||
P, L, R |
07 |
1.0 |
9.0 |
||||||
F |
07 |
1.0 |
10.0 |
||||||
Propagation delay time, MR to Q 3003 |
tPLH 4/ 5/ 13/ 14/ |
CL = 50 pF minimum RL = 500ν See figure 4 |
08 |
3.0 V |
9, 11 |
1.0 |
12.5 |
ns |
|
10 |
1.0 |
15.0 |
|||||||
08 |
4.5 V |
9, 11 |
1.0 |
9.0 |
|||||
10 |
1.0 |
11.0 |
1/ Each input/output, as applicable, shall be tested at the specified temperature for the specified limits. Output terminals not designated shall be high level logic, low level logic, or open, except as follows:
a. VIC (pos) tests, the GND terminal can be open. TC = +25°C. b. VIC (neg) tests, the VCC terminal shall be open. TC = +25°C.
c. All ICC tests, the output terminal shall be open. When performing these tests, the current meter shall be placed in the circuit such that all current flows through the meter.
For negative and positive voltage and current values, the sign designates the potential difference in reference to GND and
the direction of current flow respectively and the absolute value of the magnitude, not the sign, is relative to the minimum and maximum limits, as applicable, listed herein.
2/ The word "All" in the device type column means the value listed in the limit columns apply for all device types listed herein.
Where. M, D, P, L, R, and F in the conditions column specify the postirradiation limits for those device types specified in the device type column.
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business