3.3.1 Terminal connections. The terminal connections shall be as specified on figure 1.
3.3.2 Truth tables. The truth tables shall be as specified on figure 2.
3.3.3 Schematic circuits. The schematic circuits shall be maintained by the manufacturer and made available to the qualifying activity or preparing activity upon request.
3.3.4 Case outlines. The case outlines shall be as specified in 1.2.3 herein.
3. 4 Electrical performance characteristics and post irradiation end-point electrical parameter limits. Unless otherwise specified, the electrical performance characteristics and postirradiation end-point electrical parameter limits are as specified in table I and apply over the case operating temperature range specified. Test conditions for these specified characteristics and limits are as specified in table I.
3.5 Lead material and finish. The lead material and finish shall be in accordance with MIL-PRF-38535 (see 6.6).
3.6 Electrical test requirements. The electrical test requirements for each device class shall be the subgroups specified in table II. The electrical tests for each subgroup are described in table I. Radiation hardness assurance level M, D, P, L , R, and F (see MIL-PRF-38535) in table I are postirradiation end-point electrical parameters.
3.7 Radiation hardness assurance identifier. The radiation hardness assurance identifier shall be in accordance with
MIL-PRF-38535 and herein (see 3.6).
3.8 Marking. Marking shall be in accordance with MIL-PRF-38535. For product built in accordance with A.3.2.2 of
MIL-PRF-38535, or as modified in the manufacturer's QM plan, the "QD" certification mark shall be used in place of the "Q" or
"QML" certification mark.
3.9 Microcircuit group assignment. The devices covered by this specification shall be in microcircuit group number 38 (see
MIL-PRF-38535, appendix A).