1/ Input pins not designated may be tied to VDD (or VCC) or GND or may be left open provided they do not influence the outcome of the measurement.
Output pins not designated may be tied to the loads or may be left open provided they do not influence the outcome of the measurement.
2/
Symbol |
VIH1 |
VIL1 |
VIH2 |
VIL2 |
IOH1 |
IOL1 |
IOH2 |
IOL2 |
IOL3 |
IOL4 |
||||
Device type |
01 03 05 |
02 04 |
01 03 05 |
02 04 |
01 03 05 |
02 04 |
01 03 05 |
02 04 |
All |
All |
All |
All |
05 |
05 |
Temperature TC = 25°C |
3.95 V |
3.8 V |
0.9 V |
1.1 V |
10.25 V |
9.5 V |
2.15 V |
2.8 V |
-.1 mA |
.23 mA |
-.45 mA |
3.0 mA |
1.6 mA |
0.8 mA |
TC = 125°C |
3.85 V |
3.6 V |
0.65 V |
0.85 V |
10.0 V |
9.25 V |
1.95 V |
2.55 V |
-.1 mA |
.23 mA |
-.35 mA |
2.1 mA |
1.2 mA |
0.55 mA |
TC = -55°C |
4.05 V |
3.95 V |
0.95 V |
1.35 V |
10.5 V |
9.75 V |
2.24 V |
3.05 V |
-.1 mA |
.23 mA |
-.65 mA |
3.7 mA |
2.1 mA |
1.0 mA |
3/ Terminal 16 is not connected for device types 03 and 04.
4/ Test parameter VIC(pos) does not apply to device types 03 and 04.
5/ When performing quiescent supply current measurements (ISS), the meter shall be placed so that all currents flow through the meter.
6/ The device manufacturer may, at his option, measure IIL and IIH at 25°C for each individual input or measure all inputs together.
7/ (A) Capacitance bridge between measured terminal and VSS; frequency = 1 MHz.
8/ Test limits tPHL, tPLH, tTHL, and tTLH for device types 01/03 and 02/04 consists of two sets of values and are expressed XXX/XXXX in the limits columns. The digits preceding the slash apply to the first device in a set.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business