TABLE III. Group A inspection for device types 02 and 04 - Continued.
Symbol |
MIL- STD- 883 method |
Cases E,F,N, z |
For terminal conditions and limits, see 1/ and 2/ |
Measure d terminal |
Test limits |
Unit |
||||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 3/ |
Subgroup 9 TC = 25°C |
Subgroup 10 TC = 125°C |
Subgroup 11 TC = -55°C |
||||||||
Test no. |
VCC |
Y1 |
A1 |
Y2 |
A2 |
Y3 |
A3 |
VSS |
A4 |
Y4 |
A5 |
Y5 |
NC |
A6 |
Y6 |
VDD |
Min |
Max 8/ |
Min |
Max 8/ |
Min |
Max 8/ |
||||
tPHL " " " " " |
3003 Fig. 3 " " " " |
83 84 85 86 87 88 |
5.0V " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
GND " " " " " |
IN |
OUT |
IN |
OUT |
IN |
OUT |
5.0V " " " " " |
A1 to Y1 A2 to Y2 A3 to Y3 A4 to Y4 A5 to Y5 A6 to Y6 |
6 " " " " " |
100/ 150 " " " " |
9 " " " " " |
150/ 225 " " " " |
6 " " " " " |
100/ 150 " " " " |
ns " " " " " |
|
tPLH " " " " " |
" " " " " " |
89 90 91 92 93 94 |
" " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
" " " " " " |
IN |
OUT |
IN |
OUT |
IN |
OUT |
" " " " " " |
A1 to Y1 A2 to Y2 A3 to Y3 A4 to Y4 A5 to Y5 A6 to Y6 |
6 " " " " " |
140/ 230 " " " " |
9 " " " " " |
210/ 345 " " " " |
6 " " " " " |
140/ 230 " " " " |
" " " " " " |
|
tTHL " " " " " |
3004 Fig. 3 " " " " |
95 96 97 98 99 100 |
" " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
" " " " " " |
IN |
OUT |
IN |
OUT |
IN |
OUT |
" " " " " " |
Y1 Y2 Y3 Y4 Y5 Y6 |
6 " " " " " |
60/70 " " " " " |
9 " " " " " |
90/ 105 " " " " |
6 " " " " " |
60/70 " " " " " |
" " " " " " |
|
tTLH " " " " " |
" " " " " " |
101 102 103 104 105 106 |
" " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
" " " " " " |
IN |
OUT |
IN |
OUT |
IN |
OUT |
" " " " " " |
Y1 Y2 Y3 Y4 Y5 Y6 |
6 " " " " " |
270 " " " " " |
9 " " " " " |
405 " " " " " |
6 " " " " " |
270 " " " " " |
" " " " " " |
See footnotes at end of device type 05.