TA8LE III. Group A inspection for device type 03 - Continued.
Terminal conditions (pins not designated may be high � 2.0 V or low s 0.8 V or open).
Subgroup |
Symbol |
MIL-STD- 883 method |
Cases A,8,C,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Limits |
Unit |
|
Case 1/ 2 |
2 |
3 |
4 |
6 |
8 |
9 |
10 |
12 |
13 |
14 |
16 |
18 |
19 |
20 |
|||||||
Test no. |
1A |
18 |
1Y |
2A |
28 |
2Y |
GND |
3Y |
3A |
38 |
4Y |
4A |
48 |
VCC |
Min |
Max |
|||||
2 |
Same tests, terminal conditions and limits as for subgroup 1, except TC = +125°C and VIC tests are omitted. |
||||||||||||||||||||
3 |
Same tests, terminal conditions and limits as for subgroup 1, except TC = -55°C and VIC tests are omitted. |
||||||||||||||||||||
9 Tc = 25°C |
tPLH |
3003 Fig. 3 " " " " " " |
47 |
IN |
2.7 V |
OUT |
GND |
5.0 V |
1A to 1Y |
10 |
33 |
ns |
|||||||||
48 |
2.7 V |
IN |
OUT |
" |
" |
18 to 1Y |
" |
" |
" |
||||||||||||
49 |
IN |
2.7 V |
OUT |
" |
" |
2A to 2Y |
" |
" |
" |
||||||||||||
50 |
2.7 V |
IN |
OUT |
" |
" |
28 to 2Y |
" |
" |
" |
||||||||||||
51 |
" |
OUT |
IN |
2.7 V |
" |
3A to 3Y |
" |
" |
" |
||||||||||||
52 |
" |
OUT |
2.7 V |
IN |
" |
38 to 3Y |
" |
" |
" |
||||||||||||
53 |
" |
OUT |
IN |
2.7 V |
" |
4A to 4Y |
" |
" |
" |
||||||||||||
54 |
" |
OUT |
2.7 V |
IN |
" |
48 to 4Y |
" |
" |
" |
||||||||||||
tPHL |
" " " " " " " " |
55 |
IN |
2.7 V |
OUT |
" |
" |
1A to 1Y |
7 |
18 |
" |
||||||||||
56 |
2.7 V |
IN |
OUT |
" |
" |
18 to 1Y |
" |
" |
" |
||||||||||||
57 |
IN |
2.7 V |
OUT |
" |
" |
2A to 2Y |
" |
" |
" |
||||||||||||
58 |
2.7 V |
IN |
OUT |
" |
" |
28 to 2Y |
" |
" |
" |
||||||||||||
59 |
" |
OUT |
IN |
2.7 V |
" |
3A to 3Y |
" |
" |
" |
||||||||||||
60 |
" |
OUT |
2.7 V |
IN |
" |
38 to 3Y |
" |
" |
" |
||||||||||||
61 |
" |
OUT |
IN |
2.7 V |
" |
4A to 4Y |
" |
" |
" |
||||||||||||
62 |
" |
OUT |
2.7 V |
IN |
" |
48 to 4Y |
" |
" |
" |
||||||||||||
10 |
tPLH |
Same tests and terminal conditions as subgroup 9, except TC = +125°C. |
10 |
40 |
" |
||||||||||||||||
tPHL |
7 |
21 |
" |
||||||||||||||||||
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |
1/ For case 2, pins not referenced are N/C.
2/ IIL limits shall be as follows:
Parameters |
Min/Max limits in µA for circuit |
||
A |
8 |
C |
|
IIL |
0/-100 |
0/-100 |
0/-100 |